Certified under EPA WaterSense, Studiolux SLT500 tests at 1.28 gpf (#595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median), trimming 20.0% off the 1.6 gpf federal cap while cutting 3-person household draw by ~12,156 gal/yr versus 3.5 gpf fixtures. Compare EPA WaterSense certified flow metrics for Studiolux SLT500 WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.
- Certified Flow
- 1.28 gpf
- vs. EPAct 1992
- -20.0% (1.6 gpf)
- Annual Draw (1 Pers.)
- 2,336 gal/yr
- Annual Saved vs. Legacy
- 4,052 gal/person
- Brand EPA Count
- 3 toilets
- Series / Variants
- SLT500 (1)

What does Studiolux SLT500 Benchmark & Water Budget show?
Efficiency check: certified at 1.28 gpf, Studiolux SLT500 trims 20.0% under federal 1.6 gpf caps; #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median. Bowl SLT500B / Tank SLT500T.
For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.
Brand breadth: Studiolux holds 3 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as Liberty Utilities - Arizona (AZ) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).
Where does Studiolux SLT500 sit on the EPA WaterSense toilet flow curve?
Comparing Studiolux SLT500 (1.28 gpf) against federal EPAct (1.6 gpf) and legacy (3.5 gpf) baselines shows immediate per-use conservation.
How do subfloor levelness and rough-in height protect Studiolux SLT500?
Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.
What official WaterSense figures verify Studiolux SLT500?
Examine Studiolux SLT500 certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Registry Share | Studiolux (3 certified) | EPA WaterSense Partner |
| Model Number / Series | SLT500 | Certified Series (1 finish variants) |
| Rated Consumption | 1.28 gpf | Category median 1.28 gpf (n=3,875 rated) |
| Flush / Valve Architecture | Single / Gravity | Verify rough-in & supply pressure |
What annual utility savings does Studiolux SLT500 deliver?
Compare 1-to-4-person household water use with Studiolux SLT500 against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.
| Household Size | Annual Model Use | Saved vs. EPAct 1992 | Saved vs. Legacy ($8–$18/1k) |
|---|---|---|---|
| 1 Occupant | 2,336 gal | 584 gal | 4,052 gal (~$45) |
| 2 Occupants | 4,672 gal | 1,168 gal | 8,104 gal (~$89) |
| 3 Occupants | 7,008 gal | 1,752 gal | 12,156 gal (~$97–$219) |
| 4 Occupants | 9,344 gal | 2,336 gal | 16,208 gal (~$178) |
What alternative WaterSense models compare to Studiolux SLT500?
Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.
| Peer Brand & Model | Rated GPF (Delta) | Flush / Model Detail |
|---|---|---|
| AIMLER W.C - AC-039 / TANK... | 1.28 gpf (Same flow) | Single / Gravity |
| American Standard 2568128 | 1.28 gpf (Same flow) | Single / Gravity |
| American Standard 3332128DISP | 1.28 gpf (Same flow) | Single / Gravity |
| Aquasource 810485/T802M | 1.28 gpf (Same flow) | Single / Gravity |
| Bathroom Anywhere 42832 | 1.28 gpf (Same flow) | Single / Gravity |
What will Studiolux SLT500 save on your annual water bill?
Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.
Who should not install Studiolux SLT500 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Studiolux SLT500 for residential use.
Limitations & Who Should Skip
- Building drain lacks 1/4 in/ft slope for reduced flush carry
Best-Fit Homeowner Profiles
- Ideal fit: Meeting 1.6 gpf federal & stricter WaterSense caps
- Primary match: Targeting ~$134/yr utility savings (3-person home)
Which homeowner questions come up most for Studiolux SLT500?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Studiolux SLT500.
Can homeowners claim utility rebates when installing Studiolux SLT500?
Because Studiolux SLT500 holds active EPA WaterSense listing, it meets equipment rules across 133 tracked municipal rebate programs nationwide; confirm local utility funds before buying.
Is Studiolux SLT500 leaner than typical WaterSense toilet models?
Compared with the 1.28 gpf WaterSense toilet median, Studiolux SLT500's 1.28 gpf rating places it equal to category norms inside EPA conservation limits.
What annual dollar savings can a 3-person home expect with Studiolux SLT500?
Upgrading a 3.5 gpf legacy fixture to Studiolux SLT500 saves ~12,153 gallons yearly for three occupants, about $134/yr at $11 per 1,000 gallons combined water and sewer.
What closet flange and side-wall clearances apply to Studiolux SLT500?
IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).
How is EPA WaterSense performance tested beyond raw gpf flow caps?
EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.
Does installing Studiolux SLT500 require a municipal plumbing permit?
Like-for-like swaps using Studiolux SLT500 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.
How much water does Studiolux SLT500 save compared with EPAct 1992 and pre-1994 fixtures?
Rated at 1.28 gpf, Studiolux SLT500 cuts 20.0% below the 1.6 gpf EPAct 1992 ceiling and 63.4% under 3.5 gpf legacy units, saving 4,051 gal/person/yr (584 vs EPAct).
Who should NOT install Studiolux SLT500 without checking house plumbing first?
Homes with aging cast-iron drains, flat slopes under 1/4 in/ft, or pipe bellies should camera-check waste carry before dropping from 3.5 gpf bowls to 1.28 gpf high-efficiency flushing.
Sources
- EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
- EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)