Skip to main content
Grant Estimator

Tynan 4757.XX WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · MacLair Ultra (16 SKUs)
Verified Specification Summary

Certified under EPA WaterSense, Tynan 4757.XX tests at 0.8 gpf (#4 of 3,875 rated single-flush models (out of 6,793 certified toilets); most water-efficient 3.2% of 3,875 rated single-flush models, lower-flow than 96.8% of rated single-flush models), trimming 50.0% off the 1.6 gpf federal cap while cutting 3-person household draw by ~14,784 gal/yr versus 3.5 gpf fixtures.

Certified Flow
0.8 gpf
vs. EPAct 1992
-50.0% (1.6 gpf)
Annual Draw (1 Pers.)
1,460 gal/yr
Annual Saved vs. Legacy
4,928 gal/person
Brand EPA Count
242 toilets
Series / Variants
4757.XX (16)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does Tynan 4757.XX Benchmark & Water Budget show?

Efficiency check: certified at 0.8 gpf, Tynan 4757.XX (MacLair Ultra) trims 50.0% under federal 1.6 gpf caps; #4 of 3,875 rated single-flush models; most water-efficient 3.2% of 3,875 rated single-flush models, lower-flow than 96.8% of rated single-flush models (0.48 gpf lower-flow than the 1.28 gpf median). Bowl 0747.XX / Tank 1350.XX.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 0.8 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: Tynan holds 242 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~14,784 gallons/yr—roughly $118/yr in low-tariff towns ($8/1k gal), $163/yr at national averages ($11/1k gal), or $266/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Fairfield (CA) list active rebates among 200 U.S. programs. Closest alternatives: Aflush/Waso A2001EP (0.8 gpf) and American Standard 250AA808 (0.8 gpf).

Where does Tynan 4757.XX sit on the EPA WaterSense toilet flow curve?

Comparing Tynan 4757.XX (0.80 gpf) against federal EPAct (1.6 gpf) and legacy (3.5 gpf) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): 4757.XX: 0.80; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)4757.XX: 0.804757.XX0.80EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 0.8 gpf: 0.8 gpf (3rd percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf0.8 gpf: 0.8 gpf (P3)

How do subfloor levelness and rough-in height protect Tynan 4757.XX?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify Tynan 4757.XX?

Examine Tynan 4757.XX certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share Tynan (242 certified) EPA WaterSense Partner
Model Number / Series 4757.XX MacLair Ultra (16 finish variants)
Rated Consumption 0.8 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

Which 16 finish and trim SKUs share the Tynan 4757.XX WaterSense spec?

Manufacturer finish codes (Chrome, Brushed Nickel, Bronze, Matte Black) share identical hydraulic performance; 8 representative EPA SKU variations are consolidated below.

Finish and trim SKUs consolidated into Tynan 4757.XX (16 total certified variants)
Certified Finish SKUVerified FlowSeries Designation
4757.XX0.8 gpfMacLair Ultra
4742.XX0.8 gpfMacLair Ultra
4747.XX0.8 gpfMacLair Ultra
4752.XX0.8 gpfMacLair Ultra
4757AR.XX0.8 gpfMacLair Ultra
4747AR.XX0.8 gpfMacLair Ultra
4752A.XX0.8 gpfMacLair Ultra
4742AR.XX0.8 gpfMacLair Ultra

What annual utility savings does Tynan 4757.XX deliver?

Compare 1-to-4-person household water use with Tynan 4757.XX against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for Tynan 4757.XX (0.8 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant1,460 gal1,460 gal4,928 gal (~$54)
2 Occupants2,920 gal2,920 gal9,856 gal (~$108)
3 Occupants4,380 gal4,380 gal14,784 gal (~$118–$266)
4 Occupants5,840 gal5,840 gal19,712 gal (~$217)

What alternative WaterSense models compare to Tynan 4757.XX?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
Aflush/Waso A2001EP 0.8 gpf (Same flow) Single / Gravity
American Standard 250AA808 0.8 gpf (Same flow) Single / Gravity
American Standard 250AA809 0.8 gpf (Same flow) Single / Gravity
American Standard 251AA808 0.8 gpf (Same flow) Single / Gravity
American Standard 251AA809 0.8 gpf (Same flow) Single / Gravity

What will Tynan 4757.XX save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

When does Tynan 4757.XX fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Tynan 4757.XX.

Limitations & Who Should Skip

  • Building drain lacks 1/4 in/ft slope for reduced flush carry

Best-Fit Homeowner Profiles

  • Recommended when: Meeting 1.6 gpf federal & stricter WaterSense caps
  • Target scenario: Targeting ~$163/yr utility savings (3-person home)

Which homeowner questions come up most for Tynan 4757.XX?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Tynan 4757.XX.

What annual gallon reduction does Tynan 4757.XX achieve over older plumbing?

Testing at 0.8 gpf, Tynan 4757.XX uses 77.1% less water than 3.5 gpf pre-1994 models (50.0% below 1.6 gpf EPAct), conserving 4,928 gallons per resident each year.

When does switching to Tynan 4757.XX (0.8 gpf) require a drain inspection?

Older pre-1980 houses with corroded cast-iron branches or poor 1/4-inch-per-foot grade risk slow waste carry on 0.8 gpf flushes; verify pipe slope before replacing 3.5 gpf toilets.

How do 133 WaterSense rebate programs treat Tynan 4757.XX?

Municipal utilities among 133 EPA WaterSense partners require certified SKU listings like Tynan 4757.XX, itemized purchase invoices, and residential installation addresses.

How does Tynan 4757.XX perform relative to the EPA WaterSense category median?

Among certified WaterSense toilets, the national median stands at 1.28 gpf. At 0.8 gpf, Tynan 4757.XX sits below the category median while clearing federal WaterSense caps.

How much does a 3-resident family save yearly switching to Tynan 4757.XX?

At $11 per 1,000 gallons, a 3-person household conserving 14,784 gallons/yr with Tynan 4757.XX trims roughly $163 annually off water and sewer utility bills.

What closet flange and side-wall clearances apply to Tynan 4757.XX?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 0.8 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing Tynan 4757.XX require a municipal plumbing permit?

Like-for-like swaps using Tynan 4757.XX on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories