Skip to main content
Grant Estimator

VANCHI TT040ES-1.28 WaterSense Toilet Specifications

EPA WaterSense Certified Toilet · VANCHI (1 SKU)
Verified Specification Summary

Certified under EPA WaterSense, VANCHI TT040ES-1.28 tests at 1.28 gpf (#595 of 3,875 rated single-flush models (out of 6,793 certified toilets); tied with 3,280 other rated single-flush models at the 1.28 gpf median), trimming 20.0% off the 1.6 gpf federal cap while cutting 3-person household draw by ~12,156 gal/yr versus 3.5 gpf fixtures. Compare EPA WaterSense certified flow metrics for VANCHI TT040ES-1.28 WaterSense Toilet Specifications, annual household savings against 3.5 gpf/4.0 gpm legacy units, municipal utility rebates, and IPC closet flange clearances below.

Certified Flow
1.28 gpf
vs. EPAct 1992
-20.0% (1.6 gpf)
Annual Draw (1 Pers.)
2,336 gal/yr
Annual Saved vs. Legacy
4,052 gal/person
Brand EPA Count
8 toilets
Series / Variants
TT040ES-1.28 (1)
High-efficiency white ceramic toilet and brushed nickel faucet in a sunlit stone bathroom
WaterSense bath hardware and closet flange trim finish mounted level on finished tile.

What does VANCHI TT040ES-1.28 Benchmark & Water Budget show?

Efficiency check: certified at 1.28 gpf, VANCHI TT040ES-1.28 trims 20.0% under federal 1.6 gpf caps; #595 of 3,875 rated single-flush models; tied with 3,280 other rated single-flush models at the 1.28 gpf median.

For older homes with cast-iron sewer lines, verify 1/4-inch-per-foot drain slope before installing a 1.28 gpf bowl (Gravity flush), and consider 17-to-19-inch comfort seat height with 16-to-18-inch side-wall centerline clearance (ADA 604.2) for safer senior transfers.

Brand breadth: VANCHI holds 8 certified toilets in EPA files (median 1.28 gpf, range 0.75-1.28). For 3 residents, replacing a 3.5 gpf legacy unit saves ~12,156 gallons/yr—roughly $97/yr in low-tariff towns ($8/1k gal), $134/yr at national averages ($11/1k gal), or $219/yr in high-rate cities ($18/1k gal). Regional utilities such as City of Healdsburg (CA) list active rebates among 200 U.S. programs. Closest alternatives: AIMLER W.C - AC-039 / TANK - AC-040 (1.28 gpf) and American Standard 2568128 (1.28 gpf).

Where does VANCHI TT040ES-1.28 sit on the EPA WaterSense toilet flow curve?

Comparing VANCHI TT040ES-1.28 (1.28 gpf) against federal EPAct (1.6 gpf) and legacy (3.5 gpf) baselines shows immediate per-use conservation.

Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)Horizontal bar comparison for Flow Rating Comparison vs Federal & Legacy Thresholds (gpf) (4 items): TT040ES-1.28: 1.28; EPA Max Cap: 1.28; EPAct 1992: 1.60; Pre-1994 Legacy: 3.50.Flow Rating Comparison vs Federal & Legacy Thresholds (gpf)TT040ES-1.28: 1.28TT040ES-1.281.28EPA Max Cap: 1.28EPA Max Cap1.28EPAct 1992: 1.60EPAct 19921.60Pre-1994 Legacy: 3.50Pre-1994 Legacy3.50
Registry Flow Distribution (Toilet)Histogram of 3875 items for Registry Flow Distribution (Toilet). Min 0.75 gpf, median 1.28 gpf, max 1.28 gpf. Marker 1.28 gpf: 1.28 gpf (100th percentile).Registry Flow Distribution (Toilet)n=3875 · median 1.28 gpf0164432870.75 gpf to 0.8 gpf: 1240.8 gpf to 0.86 gpf: 00.86 gpf to 0.91 gpf: 210.91 gpf to 0.96 gpf: 190.96 gpf to 1.02 gpf: 3311.02 gpf to 1.07 gpf: 341.07 gpf to 1.12 gpf: 511.12 gpf to 1.17 gpf: 21.17 gpf to 1.23 gpf: 61.23 gpf to 1.28 gpf: 32870.75 gpf1.02 gpf1.28 gpf1.28 gpf: 1.28 gpf (P100)

How do subfloor levelness and rough-in height protect VANCHI TT040ES-1.28?

Confirm L/360 subfloor stiffness, flush-mounted closet flanges on finished tile, and 15-to-18-inch side-wall clearance before setting bath fixtures.

Self-Leveling Underlayment Primer and Toilet Flange Elevation Detail Layered floor cross-section showing L/360 joist subfloor, acrylic primer seal, compressible perimeter foam strip, poured self-leveling concrete, and closet flange seated atop finished tile. 1/4-in Perimeter Foam Sill Strip Sound Concrete or 3/4-in T&G Plywood Subfloor (L/360 Stiffness) Self-Leveling Concrete (1/8 to 1.5 in · 24 sq ft/bag @ 1/4 in) Porcelain Tile + Thinset (Flatness 1/8 in in 10 ft) Flange Sits ON TOP of Tile Mandatory acrylic primer layer prevents pinholing & flash-dry debonding
Primer, expansion perimeter dam, and closet flange elevation rules for bathroom tile floor preparation.

What official WaterSense figures verify VANCHI TT040ES-1.28?

Examine VANCHI TT040ES-1.28 certified discharge rate, manufacturer portfolio count, and residential rough-in or valve compatibility requirements from official EPA files.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Registry Share VANCHI (8 certified) EPA WaterSense Partner
Model Number / Series TT040ES-1.28 Certified Series (1 finish variants)
Rated Consumption 1.28 gpf Category median 1.28 gpf (n=3,875 rated)
Flush / Valve Architecture Single / Gravity Verify rough-in & supply pressure

What annual utility savings does VANCHI TT040ES-1.28 deliver?

Compare 1-to-4-person household water use with VANCHI TT040ES-1.28 against 1992 federal caps and pre-1994 fixtures using an illustrative $11 per 1,000 gallons rate.

Computed annual water savings for VANCHI TT040ES-1.28 (1.28 gpf)
Household SizeAnnual Model UseSaved vs. EPAct 1992Saved vs. Legacy ($8–$18/1k)
1 Occupant2,336 gal584 gal4,052 gal (~$45)
2 Occupants4,672 gal1,168 gal8,104 gal (~$89)
3 Occupants7,008 gal1,752 gal12,156 gal (~$97–$219)
4 Occupants9,344 gal2,336 gal16,208 gal (~$178)

What alternative WaterSense models compare to VANCHI TT040ES-1.28?

Cross-check five closely matched EPA certified fixtures showing exact flow deltas and mechanism or series details before ordering bathroom trim.

Peer toilet models with matching or lower gpf ratings
Peer Brand & ModelRated GPF (Delta)Flush / Model Detail
AIMLER W.C - AC-039 / TANK... 1.28 gpf (Same flow) Single / Gravity
American Standard 2568128 1.28 gpf (Same flow) Single / Gravity
American Standard 3332128DISP 1.28 gpf (Same flow) Single / Gravity
Aquasource 810485/T802M 1.28 gpf (Same flow) Single / Gravity
Bathroom Anywhere 42832 1.28 gpf (Same flow) Single / Gravity

What will VANCHI TT040ES-1.28 save on your annual water bill?

Adjust household size and local utility rate per 1,000 gallons below to compute personalized annual gallon and dollar reductions locally.

Does VANCHI TT040ES-1.28 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying VANCHI TT040ES-1.28 for your remodel.

Limitations & Who Should Skip

  • Building drain lacks 1/4 in/ft slope for reduced flush carry

Best-Fit Homeowner Profiles

  • Strong scenario: Meeting 1.6 gpf federal & stricter WaterSense caps
  • Best application: Targeting ~$134/yr utility savings (3-person home)

Which homeowner questions come up most for VANCHI TT040ES-1.28?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around VANCHI TT040ES-1.28.

Are older sewer lines safe for VANCHI TT040ES-1.28's 1.28 gpf flush volume?

Most copper/PVC lines handle 1.28 gpf cleanly, whereas sagging or scaled cast-iron laterals lacking 1/4 in/ft slope should be scoped prior to replacing 3.5 gpf bowls.

Does VANCHI TT040ES-1.28 qualify for municipal utility water rebates in 2026?

Yes, EPA WaterSense certification makes VANCHI TT040ES-1.28 eligible under qualifying programs among 133 active U.S. water utility rebates when paired with dated receipts and pre-purchase fund verification.

Where does VANCHI TT040ES-1.28 rank against other certified toilets?

Rated at 1.28 gpf, VANCHI TT040ES-1.28 measures equal to the 1.28 gpf WaterSense toilet median across thousands of EPA-listed residential fixtures.

Does VANCHI TT040ES-1.28 cut utility costs noticeably for a 3-person household?

Yes: cutting 12,153 gallons/yr relative to 3.5 gpf hardware translates to ~$134/yr in combined water/sewer savings at $11/1k gal.

What closet flange and side-wall clearances apply to VANCHI TT040ES-1.28?

IPC/IRC rules require the closet flange to sit flush atop finished tile with >=15-in side-wall centerline clearance (or 16-18 in under voluntary 2010 ADA 604.2 aging-in-place layouts).

How is EPA WaterSense performance tested beyond raw gpf flow caps?

EPA WaterSense certification pairs the 1.28 gpf cap with independent lab testing for solid waste MaP extraction (>=350g) and drain carry.

Does installing VANCHI TT040ES-1.28 require a municipal plumbing permit?

Like-for-like swaps using VANCHI TT040ES-1.28 on existing rough-ins rarely need permits, whereas moving drain stacks, altering manifolds, or disturbing >6 sq ft of pre-1978 paint triggers permit and EPA RRP rules.

What efficiency edge separates VANCHI TT040ES-1.28 from legacy and EPAct models?

Certified at 1.28 gpf, VANCHI TT040ES-1.28 achieves 20.0% savings against EPAct 1992 (1.6 gpf) and 63.4% savings against 3.5 gpf fixtures, 4,051 gallons per occupant yearly.

Sources

  1. EPA WaterSense Labeled Products Registry (Toilets, Showerheads, Lavatory Faucets) — U.S. EPA WaterSense, 2026 Bulk Export ZIP (retrieved 2026-11-23)
  2. EPA WaterSense Utility Rebate Finder API — U.S. EPA WaterSense, 2026 API (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories