Skip to main content
Grant Estimator

Aria QBV01100 Exhaust Fan Specifications

ENERGY STAR PD #3984072 · Bathroom/Utility Room · Qualified 2025-01-10
Verified Specification Summary

Homeowners specifying Aria QBV01100 gain 110 CFM at 0.1 in. w.g. (101.5 CFM at 0.25 in. w.g.) where it registers #357 of 607 in quietness (1.1 sones) and delivers 4.5 CFM/W efficacy, venting bathrooms up to 101 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Aria QBV01100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 101.5 CFM
Noise @ 0.1"
1.1 sones (#357/607)
Efficacy Rank
4.5 CFM/W (#632/1,145)
Static Retention
92.3% @ 0.25"
Motor Draw
24.4 W (8.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Aria QBV01100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 101.5 CFM out of 110 CFM (92.3% retention, 4.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Aria registers 3 certified models, with SKU QBV01100 (series: QBV) (PD #3984072) certified since 2025-01-10. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Good Housekeeping 84006 (110.0 CFM) and AERO PURE ABF110G16W (110.0 CFM).

What acoustic percentile does Aria QBV01100 occupy among 1,145 bath blowers?

Inspect how Aria QBV01100 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.1 sone: 1.1 sones (62nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.1 sone: 1.1 sones (P62)

Which exterior damper path suits Aria QBV01100 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Aria QBV01100 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Aria QBV01100 acoustic and static metrics stand?

Compare Aria QBV01100 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Aria (3 models) ENERGY STAR Certified Partner
Model Number & Series QBV01100 / QBV PD ID 3984072 (Qualified 2025-01-10)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (101.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.1 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Aria QBV01100 handle taller ceilings or walk-in tub steam?

Evaluate how Aria QBV01100 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Aria QBV01100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 101 sq ft1 CFM/sq ft @ 101.5 CFM
Tall Bath (9-ft Ceiling)Up to 90 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 51 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.9 kWh/yr (~$1.42/yr)24.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2213.7 kWh/yr (~$34.19/yr)24.4 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Aria QBV01100?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Good Housekeeping 84006 110 / 101.5 CFM 1.1 sones (Same) 4.5 CFM/W 4 in. diameter
AERO PURE ABF110G16W 110 / 83.6 CFM 1.1 sones (Same) 4.4 CFM/W 4 in. diameter
AUPU AV11A3 110 / 83.6 CFM 1.1 sones (Same) 4.4 CFM/W 4 in. diameter
Miseno MBF110AWH 110 / 83.6 CFM 1.1 sones (Same) 4.4 CFM/W 4 in. diameter
Air King AK110LS6 110 / 103.3 CFM 1.1 sones (Same) 3.9 CFM/W 6 in. diameter

Is Aria QBV01100 sized right for your shower or tub room?

Check whether Aria QBV01100 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying Aria QBV01100?

Match Aria QBV01100 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 51 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 101.5 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Aria QBV01100?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Aria QBV01100.

Where does Aria QBV01100 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Aria QBV01100.

What happens to Aria QBV01100 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Aria QBV01100 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Aria QBV01100 sit on acoustic comfort for senior homeowners?

Measuring 1.1 sones, Aria QBV01100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Aria QBV01100 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Aria QBV01100 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Aria QBV01100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Aria QBV01100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Aria QBV01100?

Aria QBV01100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Aria QBV01100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Aria QBV01100's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Aria QBV01100 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Aria QBV01100 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories