Certified by EPA ENERGY STAR, Good Housekeeping 84006 delivers 110 CFM free-air (101.5 CFM at 0.25 in. w.g.) and registers #357 of 607 in quietness (1.1 sones) and delivers 4.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 101 sq ft (8-ft height) or 90 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Good Housekeeping 84006 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 101.5 CFM
- Noise @ 0.1"
- 1.1 sones (#357/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 92.3% @ 0.25"
- Motor Draw
- 24.4 W (8.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Good Housekeeping 84006 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 101.5 CFM out of 110 CFM (92.3% retention, 4.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Good Housekeeping maintains 2 active ENERGY STAR blowers; 84006 (series: 8400) (PD #4005979) gained qualification on 2025-02-21. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Aria QBV01100 (110.0 CFM) and AERO PURE ABF110G16W (110.0 CFM).
How noisy is Good Housekeeping 84006 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Good Housekeeping 84006 measures 1.1 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Good Housekeeping 84006 airflow?
Connecting Good Housekeeping 84006 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Good Housekeeping 84006 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Good Housekeeping 84006 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Good Housekeeping (2 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 84006 / 8400 | PD ID 4005979 (Qualified 2025-02-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (101.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.1 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Good Housekeeping 84006?
Calculated coverage metrics translate Good Housekeeping 84006 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 101 sq ft | 1 CFM/sq ft @ 101.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 90 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 51 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Good Housekeeping 84006?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Aria QBV01100 | 110 / 101.5 CFM | 1.1 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| AERO PURE ABF110G16W | 110 / 83.6 CFM | 1.1 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AUPU AV11A3 | 110 / 83.6 CFM | 1.1 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| Miseno MBF110AWH | 110 / 83.6 CFM | 1.1 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| Air King AK110LS6 | 110 / 103.3 CFM | 1.1 sones (Same) | 3.9 CFM/W | 6 in. diameter |
Does Good Housekeeping 84006 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Good Housekeeping 84006 percentage capacity without sending data.
When does Good Housekeeping 84006 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Good Housekeeping 84006.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 51 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 101.5 CFM net static output
- Target scenario: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Good Housekeeping 84006?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Good Housekeeping 84006.
Does running Good Housekeeping 84006 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Good Housekeeping 84006 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Good Housekeeping 84006 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Good Housekeeping 84006's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Good Housekeeping 84006?
Good Housekeeping 84006 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Good Housekeeping 84006's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Good Housekeeping 84006's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Good Housekeeping 84006 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Good Housekeeping 84006 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Good Housekeeping 84006?
Do not force Good Housekeeping 84006 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Good Housekeeping 84006 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Good Housekeeping 84006 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Good Housekeeping 84006 disturb adjacent bedrooms during night use?
Acoustic measurement places Good Housekeeping 84006 at 1.1 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)