The Broan QT130E (QT SERIES) moves 130 CFM at 0.1 in. w.g. (114.4 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones), and delivers 4.0 CFM/W efficacy, sizing bathrooms up to 114 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QT130E Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 114.4 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 88.0% @ 0.25"
- Motor Draw
- 32.5 W (11.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan QT130E vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 114.4 CFM out of 130 CFM (88.0% retention, 0.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Broan's 207-unit lineup, QT130E (series: QT SERIES) carries PD #4429507 dating to 2025-06-06. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.5 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 284.7 kWh/yr (~$45.55/yr) continuously. Closest competing matches include KOHLER 34454 (130.0 CFM) and KOHLER 34454-NA (130.0 CFM).
Where does Broan QT130E sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 2.0 sones against all 1,145 EPA listings.
How does duct geometry alter Broan QT130E static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan QT130E?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan QT130E alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | QT130E / QT SERIES | PD ID 4429507 (Qualified 2025-06-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (114.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Broan QT130E ventilate safely?
Sizing outputs below convert Broan QT130E tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 114 sq ft | 1 CFM/sq ft @ 114.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 101 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 64 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 284.7 kWh/yr (~$45.55/yr) | 32.5 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan QT130E closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KOHLER 34454 | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |
| KOHLER 34454-NA | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |
| KOHLER 34456 | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |
| KOHLER 34456-NA | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |
| KOHLER K-34454 | 130 / 106 CFM | Unpublished | 3.9 CFM/W | 4 in. diameter |
Will Broan QT130E clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan QT130E satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does Broan QT130E suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan QT130E for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 64 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 114 sq ft with 8-ft ceilings (101 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Broan QT130E?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan QT130E.
What acoustic sone tier does Broan QT130E occupy in EPA filings?
With 2.0 sones at 0.1 in. w.g., Broan QT130E produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Broan QT130E add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan QT130E averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan QT130E pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QT130E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan QT130E?
Broan QT130E features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan QT130E's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QT130E's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan QT130E pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan QT130E easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan QT130E in a bathroom remodel?
Avoid specifying Broan QT130E in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan QT130E airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan QT130E achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)