In EPA dataset 8dv7-nngq, Delta 130HS tests at 130 CFM free discharge (108.1 CFM at 0.25 in. w.g.) and registers #522 of 607 in quietness (2.0 sones) and delivers 6.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 108 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 130HS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 108.1 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 6.7 CFM/W (#431/1,145)
- Static Retention
- 83.2% @ 0.25"
- Motor Draw
- 19.4 W (7.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta 130HS vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 130 CFM open-air to 108.1 CFM at 0.25 in. w.g. (83.2% retention, 4.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places 130HS (series: DeltaSignature) (PD #2268990) among 121 Delta entries qualified through 2016-06-03. Lighting kit: No. At 6.7 CFM/W (#431 of 1,145, top 37.7% of 1,145 rated models, more efficient than 62.3% of rated models, 2.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 19.4 watts, about 7.1 kWh/yr (~$1.14/yr at $0.16/kWh) for 1 hr/day shower timers or 169.9 kWh/yr (~$27.18/yr) continuously. Closest competing matches include Fantech FR 125 (411332) (130.0 CFM) and Fantech Rn 1 (89051) (130.0 CFM).
Does Delta 130HS fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta 130HS at 2.0 sones.
Why avoid unvented attic termination with Delta 130HS?
Under ASHRAE 62.2 best practice, Delta 130HS needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Delta 130HS?
Before cutting ceiling drywall or sizing attic transitions for Delta 130HS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 130HS / DeltaSignature | PD ID 2268990 (Qualified 2016-06-03) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (108.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Delta 130HS?
Bathroom ventilation sizing below maps Delta 130HS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 108 sq ft | 1 CFM/sq ft @ 108.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 58 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.1 kWh/yr (~$1.14/yr) | 19.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 169.9 kWh/yr (~$27.18/yr) | 19.4 W x 8,760 hrs / 1,000 |
What peer models sit nearest Delta 130HS in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta 130HS.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Fantech FR 125 (411332) | 130 / N/A CFM | Unpublished | 7.0 CFM/W | 5 in. diameter |
| Fantech Rn 1 (89051) | 130 / N/A CFM | Unpublished | 7.3 CFM/W | 5 in. diameter |
| Fantech Rn1-C (606281) | 130 / N/A CFM | Unpublished | 7.3 CFM/W | 5 in. diameter |
| Panasonic FV-13NLFS1 | 130 / N/A CFM | Unpublished | 7.5 CFM/W | 6 in. diameter |
| Panasonic FV-13NLFSC1 | 130 / N/A CFM | Unpublished | 7.5 CFM/W | 6 in. diameter |
What percentage of room demand does Delta 130HS cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta 130HS tested delivery.
What plumbing or duct constraints rule out Delta 130HS?
Compare where Delta 130HS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 108.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 2.0 sones up to 108 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Delta 130HS?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta 130HS.
Why might a contractor swap Delta 130HS for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta 130HS lacks adequate reserve.
How does Delta 130HS handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta 130HS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Delta 130HS quiet enough for a primary bedroom bathroom?
At 2.0 sones, Delta 130HS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Delta 130HS energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta 130HS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 130HS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta 130HS?
Delta 130HS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta 130HS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 130HS's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Delta 130HS serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta 130HS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)