Rated for 130 CFM open-air (unpublished 0.25 in. w.g. output), Fantech FR 125 (411332) omits a published 0.1-inch sone rating and delivers 7.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 130 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FR 125 (411332) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.0 CFM/W (#420/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 18.6 W (6.8 kWh/yr)
- Duct & Tier
- 5 in. diameter · Most Eff.

What does Fantech FR 125 (411332) vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech FR 125 (411332) (EPA filing PD #2403417) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 5 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 5 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Fantech FR 125 (411332) (series: FR Series) under PD #2403417 (52 models registered, 2022-10-21). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).
How do flex elbows choke Fantech FR 125 (411332) at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 5 in. diameter metal pipe keeps Fantech FR 125 (411332) moving full rated CFM.
Does Fantech FR 125 (411332) meet residential exhaust fan code specs?
Inspect Fantech FR 125 (411332) mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FR 125 (411332) / FR Series | PD ID 2403417 (Qualified 2022-10-21) |
| Duct Connection | 5 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (130 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Fantech FR 125 (411332) airflow output?
Annual electricity figures and room square-footage ceilings below reflect Fantech FR 125 (411332) tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 130 sq ft | 1 CFM/sq ft @ 130 CFM |
| Tall Bath (9-ft Ceiling) | Up to 115 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 80 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.8 kWh/yr (~$1.09/yr) | 18.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 162.9 kWh/yr (~$26.06/yr) | 18.6 W x 8,760 hrs / 1,000 |
Which competing models share Fantech FR 125 (411332) airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
How much airflow margin does Fantech FR 125 (411332) give your bath?
Run a quick local room-volume check for Fantech FR 125 (411332) by entering square footage and ceiling height to spot under-vented steam risks early.
What plumbing or duct constraints rule out Fantech FR 125 (411332)?
Compare where Fantech FR 125 (411332) excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 80 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 130 sq ft with 8-ft ceilings (115 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 5 in. diameter
What should homeowners verify first about Fantech FR 125 (411332)?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Fantech FR 125 (411332).
Can Fantech FR 125 (411332) serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Fantech FR 125 (411332) supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Fantech FR 125 (411332) for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Fantech FR 125 (411332) lacks adequate reserve.
How does Fantech FR 125 (411332) handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Fantech FR 125 (411332) yields unlisted 0.25 in. w.g. backpressure figures, so smooth 5 in. diameter rigid metal ducting protects real exhaust.
Is Fantech FR 125 (411332) quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Fantech FR 125 (411332) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Fantech FR 125 (411332) energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Fantech FR 125 (411332) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FR 125 (411332)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech FR 125 (411332)?
Fantech FR 125 (411332) features a 5 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech FR 125 (411332)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FR 125 (411332)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)