Tested under HVI protocols, the Broan QT130E exhaust unit achieves 130 CFM at 0.1 in. w.g. (130.4 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 4.7 CFM/W efficacy, covering standard baths up to 130 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QT130E Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 130.4 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.7 CFM/W (#545/1,145)
- Static Retention
- 100.3% @ 0.25"
- Motor Draw
- 27.7 W (10.1 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan QT130E vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 130.4 CFM out of 130 CFM (100.3% retention, 12.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #4429508 verifies QT130E (series: QT SERIES) under Broan (207 listed models, qualified 2025-06-06). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 27.7 watts, about 10.1 kWh/yr (~$1.62/yr at $0.16/kWh) for 1 hr/day shower timers or 242.7 kWh/yr (~$38.83/yr) continuously. Closest competing matches include Nutone QTN130LE1 (130.0 CFM) and Greenheck SP-B110ES (118.0 CFM).
Where do Broan QT130E sones rank across EPA ENERGY STAR fans?
Comparing Broan QT130E (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Broan QT130E CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan QT130E, preventing premature peeling paint and mold growth.
How does Broan QT130E measure up on airflow and noise ratings?
Each row below breaks down Broan QT130E certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | QT130E / QT SERIES | PD ID 4429508 (Qualified 2025-06-06) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (130.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan QT130E CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 130 sq ft | 1 CFM/sq ft @ 130.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 115 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 80 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.1 kWh/yr (~$1.62/yr) | 27.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 242.7 kWh/yr (~$38.83/yr) | 27.7 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan QT130E?
Compare Broan QT130E side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| Greenheck SP-B110ES | 118 / 100 CFM | 1.5 sones (Same) | 4.0 CFM/W | 6 in. diameter |
| KORA SBF110N | 119.2 / N/A CFM | 1.6 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones (+0.20) | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones (Same) | 4.5 CFM/W | 6 in. diameter |
Can you size Broan QT130E for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan QT130E verified capacity.
Where should contractors skip Broan QT130E on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan QT130E carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 130.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around 1.5 sones up to 130 sq ft
- Works well for: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Broan QT130E?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan QT130E.
How loud is Broan QT130E compared with a standard 3.0 sone builder fan?
Tested at 1.5 sones, Broan QT130E produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Broan QT130E consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan QT130E draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan QT130E pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QT130E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan QT130E?
Broan QT130E features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan QT130E's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QT130E's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan QT130E score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan QT130E delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Broan QT130E?
Rule out Broan QT130E when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Broan QT130E capacity?
Because static drag at 0.25 in. w.g. lowers Broan QT130E from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)