In EPA dataset 8dv7-nngq, Tech Drive TD-BF-24L-5CCT(BL) tests at 150 CFM free discharge (138.2 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 138 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-24L-5CCT(BL) Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 138.2 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 92.1% @ 0.25"
- Motor Draw
- 33.3 W (12.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Tech Drive TD-BF-24L-5CCT(BL) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 138.2 CFM out of 150 CFM (92.1% retention, 4.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms Tech Drive TD-BF-24L-5CCT(BL) (series: TD) under PD #4697634 (27 models registered, 2026-09-02). Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Broan ALT4306SS (160.0 CFM).
Does Tech Drive TD-BF-24L-5CCT(BL) fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Tech Drive TD-BF-24L-5CCT(BL) at 1.5 sones.
Why avoid unvented attic termination with Tech Drive TD-BF-24L-5CCT(BL)?
Under ASHRAE 62.2 best practice, Tech Drive TD-BF-24L-5CCT(BL) needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Tech Drive TD-BF-24L-5CCT(BL)?
Before cutting ceiling drywall or sizing attic transitions for Tech Drive TD-BF-24L-5CCT(BL), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-BF-24L-5CCT(BL) / TD | PD ID 4697634 (Qualified 2026-09-02) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (138.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Tech Drive TD-BF-24L-5CCT(BL)?
Bathroom ventilation sizing below maps Tech Drive TD-BF-24L-5CCT(BL) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 138 sq ft | 1 CFM/sq ft @ 138.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 122 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 88 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |
What peer models sit nearest Tech Drive TD-BF-24L-5CCT(BL) in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Tech Drive TD-BF-24L-5CCT(BL).
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones (Same) | 3.2 CFM/W | 7 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones (+0.20) | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones (Same) | 4.5 CFM/W | 6 in. diameter |
What percentage of room demand does Tech Drive TD-BF-24L-5CCT(BL) cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Tech Drive TD-BF-24L-5CCT(BL) tested delivery.
Which bath layouts should avoid specifying Tech Drive TD-BF-24L-5CCT(BL)?
Match Tech Drive TD-BF-24L-5CCT(BL) directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 138.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 1.5 sones up to 138 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Tech Drive TD-BF-24L-5CCT(BL)?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Tech Drive TD-BF-24L-5CCT(BL).
What does Tech Drive TD-BF-24L-5CCT(BL) cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Tech Drive TD-BF-24L-5CCT(BL) 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Tech Drive TD-BF-24L-5CCT(BL) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-24L-5CCT(BL)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive TD-BF-24L-5CCT(BL)?
Tech Drive TD-BF-24L-5CCT(BL) features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive TD-BF-24L-5CCT(BL)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-24L-5CCT(BL)'s safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Tech Drive TD-BF-24L-5CCT(BL) ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-24L-5CCT(BL) covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Tech Drive TD-BF-24L-5CCT(BL) run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Tech Drive TD-BF-24L-5CCT(BL).
What happens to Tech Drive TD-BF-24L-5CCT(BL) CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Tech Drive TD-BF-24L-5CCT(BL) moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Tech Drive TD-BF-24L-5CCT(BL) sit on acoustic comfort for senior homeowners?
Measuring 1.5 sones, Tech Drive TD-BF-24L-5CCT(BL) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)