Rated for 160 CFM open-air (unpublished 0.25 in. w.g. output), Broan ALT4306SS registers #412 of 607 in quietness (1.5 sones) and delivers 3.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 160 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan ALT4306SS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
160 / N/A CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
3.2 CFM/W (#1,091/1,145)
Static Retention
0.1" test only
Motor Draw
50.0 W (18.2 kWh/yr)
Duct & Tier
7 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan ALT4306SS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU ALT4306SS (series: RANGE HOOD) (PD #4481123) certified since 2025-03-21. Lighting kit: Yes. At 3.2 CFM/W (#1,091 of 1,145, below median tier among 1,145 rated models; more efficient than 4.0% of rated models, 1.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 50.0 watts, about 18.2 kWh/yr (~$2.91/yr at $0.16/kWh) for 1 hr/day shower timers or 438.0 kWh/yr (~$70.08/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Broan QT150LE (150.0 CFM).

How does Broan ALT4306SS acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan ALT4306SS (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke Broan ALT4306SS at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 7 in. diameter metal pipe keeps Broan ALT4306SS moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan ALT4306SS meet residential exhaust fan code specs?

Inspect Broan ALT4306SS mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series ALT4306SS / RANGE HOOD PD ID 4481123 (Qualified 2025-03-21)
Duct Connection 7 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (160 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Broan ALT4306SS airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan ALT4306SS tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan ALT4306SS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 160 sq ft1 CFM/sq ft @ 160 CFM
Tall Bath (9-ft Ceiling)Up to 142 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 110 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)18.2 kWh/yr (~$2.91/yr)50.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2438.0 kWh/yr (~$70.08/yr)50.0 W x 8,760 hrs / 1,000

Which competing models share Broan ALT4306SS airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones (Same) 4.5 CFM/W 6 in. diameter
Broan QT150LE 150 / 126.1 CFM 1.5 sones (Same) 4.5 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones (+0.20) 5.3 CFM/W 4.5 x 6 in. rectangular
Best UCB3I30BLSB 160 / N/A CFM Unpublished 3.2 CFM/W 3.25 in. diameter
Best UCB3I30SBB 160 / N/A CFM Unpublished 3.2 CFM/W 3.25 in. diameter

How much airflow margin does Broan ALT4306SS give your bath?

Run a quick local room-volume check for Broan ALT4306SS by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Broan ALT4306SS on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan ALT4306SS carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 110 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 160 sq ft with 8-ft ceilings (142 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 7 in. diameter

What should homeowners verify first about Broan ALT4306SS?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan ALT4306SS.

Will long attic ducting choke Broan ALT4306SS capacity?

Because static drag at 0.25 in. w.g. lowers Broan ALT4306SS from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 7 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan ALT4306SS compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, Broan ALT4306SS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Broan ALT4306SS consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan ALT4306SS draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan ALT4306SS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan ALT4306SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan ALT4306SS?

Broan ALT4306SS features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan ALT4306SS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan ALT4306SS's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan ALT4306SS score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan ALT4306SS delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Broan ALT4306SS?

Rule out Broan ALT4306SS when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.