Delta GBR100 Exhaust Fan Specifications

ENERGY STAR PD #2323430 · Bathroom/Utility Room · Qualified 2018-07-27
Verified Specification Summary

In EPA dataset 8dv7-nngq, Delta GBR100 tests at 100 CFM free discharge (81.4 CFM at 0.25 in. w.g.) and registers #405 of 607 in quietness (1.4 sones) and delivers 7.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 81 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta GBR100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 81.4 CFM
Noise @ 0.1"
1.4 sones (#405/607)
Efficacy Rank
7.9 CFM/W (#356/1,145)
Static Retention
81.4% @ 0.25"
Motor Draw
12.7 W (4.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta GBR100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.4 sones (#405 of 607 rated models, 0.40 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 81.4 CFM at 0.25 in. w.g. (81.4% retention, 6.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta GBR100 (series: BreezGreenBuilder) under PD #2323430 (121 models registered, 2018-07-27). Lighting kit: No. At 7.9 CFM/W (#356 of 1,145, top 31.8% of 1,145 rated models, more efficient than 68.2% of rated models, 3.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.7 watts, about 4.6 kWh/yr (~$0.74/yr at $0.16/kWh) for 1 hr/day shower timers or 111.3 kWh/yr (~$17.81/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).

Does Delta GBR100 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta GBR100 at 1.4 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.4 sone: 1.4 sones (68th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.4 sone: 1.4 sones (P68)

Why avoid unvented attic termination with Delta GBR100?

Under ASHRAE 62.2 best practice, Delta GBR100 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Delta GBR100?

Before cutting ceiling drywall or sizing attic transitions for Delta GBR100, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series GBR100 / BreezGreenBuilder PD ID 2323430 (Qualified 2018-07-27)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (81.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Delta GBR100?

Bathroom ventilation sizing below maps Delta GBR100 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Delta GBR100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 81 sq ft1 CFM/sq ft @ 81.4 CFM
Tall Bath (9-ft Ceiling)Up to 72 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 31 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.6 kWh/yr (~$0.74/yr)12.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2111.3 kWh/yr (~$17.81/yr)12.7 W x 8,760 hrs / 1,000

What peer models sit nearest Delta GBR100 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta GBR100.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones (+0.10) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones (+0.10) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones (+0.10) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-MB 100 / 84.9 CFM 1.5 sones (+0.10) 7.8 CFM/W 4 in. diameter
Utilitech 7115-03 100 / 89.9 CFM 1.5 sones (+0.10) 7.8 CFM/W 4 in. diameter

What percentage of room demand does Delta GBR100 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta GBR100 tested delivery.

What plumbing or duct constraints rule out Delta GBR100?

Compare where Delta GBR100 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 81.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 1.4 sones up to 81 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Delta GBR100?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta GBR100.

Is Delta GBR100 quiet enough for a primary bedroom bathroom?

At 1.4 sones, Delta GBR100 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Delta GBR100 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta GBR100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta GBR100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta GBR100?

Delta GBR100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta GBR100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta GBR100's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta GBR100 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta GBR100 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Delta GBR100 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta GBR100 lacks adequate reserve.

How does Delta GBR100 handle 0.25 in. w.g. duct static pressure loss?