Skip to main content
Grant Estimator

Utilitech 7115-02 Exhaust Fan Specifications

ENERGY STAR PD #2406847 · Bathroom/Utility Room · Qualified 2023-01-13
Verified Specification Summary

Tested under HVI protocols, the Utilitech 7115-02 exhaust unit achieves 100 CFM at 0.1 in. w.g. (84.9 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 7.8 CFM/W efficacy, covering standard baths up to 84 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7115-02 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 84.9 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
7.8 CFM/W (#365/1,145)
Static Retention
84.9% @ 0.25"
Motor Draw
12.8 W (4.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Utilitech 7115-02 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.9 CFM at 0.25 in. w.g. (84.9% retention, 2.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2406847 verifies 7115-02 (series: Utilitech) under Utilitech (22 listed models, qualified 2023-01-13). Lighting kit: Yes. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.8 watts, about 4.7 kWh/yr (~$0.75/yr at $0.16/kWh) for 1 hr/day shower timers or 112.1 kWh/yr (~$17.94/yr) continuously. Closest competing matches include Delta ITG100ELED (100.0 CFM) and Delta ITG100RLED (100.0 CFM).

Where do Utilitech 7115-02 sones rank across EPA ENERGY STAR fans?

Comparing Utilitech 7115-02 (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

What attic duct routing preserves Utilitech 7115-02 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Utilitech 7115-02, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Utilitech 7115-02 measure up on airflow and noise ratings?

Each row below breaks down Utilitech 7115-02 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Utilitech (22 models) ENERGY STAR Certified Partner
Model Number & Series 7115-02 / Utilitech PD ID 2406847 (Qualified 2023-01-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (84.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Utilitech 7115-02 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Utilitech 7115-02
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 84 sq ft1 CFM/sq ft @ 84.9 CFM
Tall Bath (9-ft Ceiling)Up to 75 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 34 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.7 kWh/yr (~$0.75/yr)12.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2112.1 kWh/yr (~$17.94/yr)12.8 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Utilitech 7115-02?

Compare Utilitech 7115-02 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Delta ITG100 100 / 88 CFM 1.5 sones (Same) 7.6 CFM/W 4 in. diameter
Delta 100LED 100 / 75 CFM 1.5 sones (Same) 7.4 CFM/W 4 in. diameter
Delta GBR100LED 100 / 75 CFM 1.5 sones (Same) 7.4 CFM/W 4 in. diameter

Can you size Utilitech 7115-02 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Utilitech 7115-02 verified capacity.

Which bath layouts should avoid specifying Utilitech 7115-02?

Match Utilitech 7115-02 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 84.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around 1.5 sones up to 84 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Utilitech 7115-02?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Utilitech 7115-02.

What bathroom square footage can Utilitech 7115-02 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7115-02 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Utilitech 7115-02 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Utilitech 7115-02.

What happens to Utilitech 7115-02 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Utilitech 7115-02 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Utilitech 7115-02 sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Utilitech 7115-02 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Utilitech 7115-02 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Utilitech 7115-02 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Utilitech 7115-02 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7115-02's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Utilitech 7115-02?

Utilitech 7115-02 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Utilitech 7115-02's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7115-02's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories