Skip to main content
Grant Estimator

Delta ITG100ELED Exhaust Fan Specifications

ENERGY STAR PD #2406846 · Bathroom/Utility Room · Qualified 2023-01-13
Verified Specification Summary

The Delta ITG100ELED (BreezIntegrity) moves 100 CFM at 0.1 in. w.g. (84.9 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 7.8 CFM/W efficacy, sizing bathrooms up to 84 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ITG100ELED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 84.9 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
7.8 CFM/W (#365/1,145)
Static Retention
84.9% @ 0.25"
Motor Draw
12.8 W (4.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta ITG100ELED vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.9 CFM at 0.25 in. w.g. (84.9% retention, 2.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta ITG100ELED (series: BreezIntegrity) under PD #2406846 (121 models registered, 2023-01-13). Lighting kit: Yes. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.8 watts, about 4.7 kWh/yr (~$0.75/yr at $0.16/kWh) for 1 hr/day shower timers or 112.1 kWh/yr (~$17.94/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).

Where does Delta ITG100ELED sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How does duct geometry alter Delta ITG100ELED static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Delta ITG100ELED?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta ITG100ELED alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series ITG100ELED / BreezIntegrity PD ID 2406846 (Qualified 2023-01-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (84.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Delta ITG100ELED ventilate safely?

Sizing outputs below convert Delta ITG100ELED tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Delta ITG100ELED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 84 sq ft1 CFM/sq ft @ 84.9 CFM
Tall Bath (9-ft Ceiling)Up to 75 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 34 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.7 kWh/yr (~$0.75/yr)12.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2112.1 kWh/yr (~$17.94/yr)12.8 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Delta ITG100ELED closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-MB 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Utilitech 7115-03 100 / 89.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter

Will Delta ITG100ELED clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Delta ITG100ELED satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

What plumbing or duct constraints rule out Delta ITG100ELED?

Compare where Delta ITG100ELED excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 34 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 84 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Delta ITG100ELED?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta ITG100ELED.

Why might a contractor swap Delta ITG100ELED for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta ITG100ELED lacks adequate reserve.

How does Delta ITG100ELED handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta ITG100ELED yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Delta ITG100ELED quiet enough for a primary bedroom bathroom?

At 1.5 sones, Delta ITG100ELED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Delta ITG100ELED energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta ITG100ELED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ITG100ELED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta ITG100ELED?

Delta ITG100ELED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta ITG100ELED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ITG100ELED's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta ITG100ELED serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta ITG100ELED supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories