In EPA dataset 8dv7-nngq, Delta ITG100RLED tests at 100 CFM free discharge (89.9 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 7.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 89 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ITG100RLED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 89.9 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 7.8 CFM/W (#365/1,145)
- Static Retention
- 89.9% @ 0.25"
- Motor Draw
- 12.8 W (4.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta ITG100RLED vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 89.9 CFM out of 100 CFM (89.9% retention, 2.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Delta maintains 121 active ENERGY STAR blowers; ITG100RLED (series: BreezIntegrity) (PD #2346022) gained qualification on 2019-08-23. Lighting kit: Yes. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.8 watts, about 4.7 kWh/yr (~$0.75/yr at $0.16/kWh) for 1 hr/day shower timers or 112.1 kWh/yr (~$17.94/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).
Does Delta ITG100RLED fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta ITG100RLED at 1.5 sones.
Why avoid unvented attic termination with Delta ITG100RLED?
Under ASHRAE 62.2 best practice, Delta ITG100RLED needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Delta ITG100RLED?
Before cutting ceiling drywall or sizing attic transitions for Delta ITG100RLED, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ITG100RLED / BreezIntegrity | PD ID 2346022 (Qualified 2019-08-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (89.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Delta ITG100RLED?
Bathroom ventilation sizing below maps Delta ITG100RLED motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.7 kWh/yr (~$0.75/yr) | 12.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 112.1 kWh/yr (~$17.94/yr) | 12.8 W x 8,760 hrs / 1,000 |
What peer models sit nearest Delta ITG100RLED in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta ITG100RLED.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-MB | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-03 | 100 / 89.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
What percentage of room demand does Delta ITG100RLED cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta ITG100RLED tested delivery.
Where should contractors skip Delta ITG100RLED on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta ITG100RLED carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 89.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around 1.5 sones up to 89 sq ft
- Works well for: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Delta ITG100RLED?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta ITG100RLED.
How loud is Delta ITG100RLED compared with a standard 3.0 sone builder fan?
Tested at 1.5 sones, Delta ITG100RLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Delta ITG100RLED consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Delta ITG100RLED draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Delta ITG100RLED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ITG100RLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta ITG100RLED?
Delta ITG100RLED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta ITG100RLED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ITG100RLED's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Delta ITG100RLED score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta ITG100RLED delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Delta ITG100RLED?
Rule out Delta ITG100RLED when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Delta ITG100RLED capacity?
Because static drag at 0.25 in. w.g. lowers Delta ITG100RLED from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.