In EPA dataset 8dv7-nngq, Fantech SMPL100L (484303) tests at 100 CFM free discharge (91.2 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 91 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SMPL100L (484303) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 91.2 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 91.2% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Fantech SMPL100L (484303) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 91.2 CFM out of 100 CFM (91.2% retention, 3.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places SMPL100L (484303) (series: bathfan Simple) (PD #2507883) among 52 Fantech entries qualified through 2023-05-19. Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Anzzi EF-AZ106MB (100.0 CFM) and Anzzi EF-AZ106WH (100.0 CFM).
Does Fantech SMPL100L (484303) fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Fantech SMPL100L (484303) at 1.5 sones.
Why avoid unvented attic termination with Fantech SMPL100L (484303)?
Under ASHRAE 62.2 best practice, Fantech SMPL100L (484303) needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Fantech SMPL100L (484303)?
Before cutting ceiling drywall or sizing attic transitions for Fantech SMPL100L (484303), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SMPL100L (484303) / bathfan Simple | PD ID 2507883 (Qualified 2023-05-19) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (91.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Fantech SMPL100L (484303)?
Bathroom ventilation sizing below maps Fantech SMPL100L (484303) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 91 sq ft | 1 CFM/sq ft @ 91.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 41 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
What peer models sit nearest Fantech SMPL100L (484303) in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech SMPL100L (484303).
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Anzzi EF-AZ106MB | 100 / 92.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Anzzi EF-AZ106WH | 100 / 92.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Hunter 90064A | 100 / 89.6 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Hunter 90065A | 100 / 89.6 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| ACIQ AES100 | 100 / 90.2 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
What percentage of room demand does Fantech SMPL100L (484303) cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech SMPL100L (484303) tested delivery.
When does Fantech SMPL100L (484303) fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech SMPL100L (484303).
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 91.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 1.5 sones up to 91 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Fantech SMPL100L (484303)?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech SMPL100L (484303).
How much airflow does Fantech SMPL100L (484303) retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Fantech SMPL100L (484303) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Fantech SMPL100L (484303) disturb adjacent bedrooms during night use?
Acoustic measurement places Fantech SMPL100L (484303) at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Fantech SMPL100L (484303) continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Fantech SMPL100L (484303) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Fantech SMPL100L (484303) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SMPL100L (484303)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech SMPL100L (484303)?
Fantech SMPL100L (484303) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech SMPL100L (484303)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SMPL100L (484303)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Is Fantech SMPL100L (484303) code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech SMPL100L (484303) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Fantech SMPL100L (484303)?
Do not force Fantech SMPL100L (484303) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)