Hunter 90064A Exhaust Fan Specifications

ENERGY STAR PD #4498420 · Bathroom/Utility Room · Qualified 2025-09-05
Verified Specification Summary

Tested under HVI protocols, the Hunter 90064A exhaust unit achieves 100 CFM at 0.1 in. w.g. (89.6 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 89 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Hunter 90064A Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 89.6 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
89.6% @ 0.25"
Motor Draw
25.6 W (9.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Hunter 90064A vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 89.6 CFM out of 100 CFM (89.6% retention, 1.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Hunter's 4-unit lineup, 90064A (series: 90064A) carries PD #4498420 dating to 2025-09-05. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Anzzi EF-AZ106MB (100.0 CFM) and Anzzi EF-AZ106WH (100.0 CFM).

Where do Hunter 90064A sones rank across EPA ENERGY STAR fans?

Comparing Hunter 90064A (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

What attic duct routing preserves Hunter 90064A CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Hunter 90064A, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Hunter 90064A measure up on airflow and noise ratings?

Each row below breaks down Hunter 90064A certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Hunter (4 models) ENERGY STAR Certified Partner
Model Number & Series 90064A / 90064A PD ID 4498420 (Qualified 2025-09-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (89.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Hunter 90064A CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Hunter 90064A
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 89 sq ft1 CFM/sq ft @ 89.6 CFM
Tall Bath (9-ft Ceiling)Up to 79 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 39 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.3 kWh/yr (~$1.49/yr)25.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2224.3 kWh/yr (~$35.89/yr)25.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Hunter 90064A?

Compare Hunter 90064A side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Anzzi EF-AZ106MB 100 / 92.8 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Anzzi EF-AZ106WH 100 / 92.8 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Fantech SMPL100 (484302) 100 / 91.2 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Fantech SMPL100L (484303) 100 / 91.2 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
ACIQ AES100 100 / 90.2 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter

Can you size Hunter 90064A for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Hunter 90064A verified capacity.

Which bath layouts should avoid specifying Hunter 90064A?

Match Hunter 90064A directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 89.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around 1.5 sones up to 89 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Hunter 90064A?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Hunter 90064A.

What happens to Hunter 90064A CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Hunter 90064A moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Hunter 90064A sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Hunter 90064A produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Hunter 90064A cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Hunter 90064A 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Hunter 90064A pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Hunter 90064A's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Hunter 90064A?

Hunter 90064A features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Hunter 90064A's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Hunter 90064A's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Hunter 90064A ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Hunter 90064A covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Hunter 90064A run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Hunter 90064A.