Anzzi EF-AZ106MB Exhaust Fan Specifications

ENERGY STAR PD #3442050 · Bathroom/Utility Room · Qualified 2024-04-19
Verified Specification Summary

Rated for 100 CFM open-air (92.8 CFM at 0.25 in. w.g.), Anzzi EF-AZ106MB registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 92 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ106MB Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 92.8 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.0 CFM/W (#847/1,145)
Static Retention
92.8% @ 0.25"
Motor Draw
25.0 W (9.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Anzzi EF-AZ106MB vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 92.8 CFM out of 100 CFM (92.8% retention, 5.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3442050 verifies EF-AZ106MB (series: EF) under Anzzi (8 listed models, qualified 2024-04-19). Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Fantech SMPL100 (484302) (100.0 CFM) and Fantech SMPL100L (484303) (100.0 CFM).

How does Anzzi EF-AZ106MB acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Anzzi EF-AZ106MB (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke Anzzi EF-AZ106MB at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Anzzi EF-AZ106MB moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Anzzi EF-AZ106MB meet residential exhaust fan code specs?

Inspect Anzzi EF-AZ106MB mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Anzzi (8 models) ENERGY STAR Certified Partner
Model Number & Series EF-AZ106MB / EF PD ID 3442050 (Qualified 2024-04-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (92.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Anzzi EF-AZ106MB airflow output?

Annual electricity figures and room square-footage ceilings below reflect Anzzi EF-AZ106MB tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Anzzi EF-AZ106MB
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 92 sq ft1 CFM/sq ft @ 92.8 CFM
Tall Bath (9-ft Ceiling)Up to 82 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 42 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.1 kWh/yr (~$1.46/yr)25.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2219.0 kWh/yr (~$35.04/yr)25.0 W x 8,760 hrs / 1,000

Which competing models share Anzzi EF-AZ106MB airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Fantech SMPL100 (484302) 100 / 91.2 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Fantech SMPL100L (484303) 100 / 91.2 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Hunter 90064A 100 / 89.6 CFM 1.5 sones (Same) 3.9 CFM/W 4 in. diameter
Hunter 90065A 100 / 89.6 CFM 1.5 sones (Same) 3.9 CFM/W 4 in. diameter
ACIQ AES100 100 / 90.2 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter

How much airflow margin does Anzzi EF-AZ106MB give your bath?

Run a quick local room-volume check for Anzzi EF-AZ106MB by entering square footage and ceiling height to spot under-vented steam risks early.

When does Anzzi EF-AZ106MB fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Anzzi EF-AZ106MB.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 42 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 92 sq ft with 8-ft ceilings (82 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Anzzi EF-AZ106MB?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Anzzi EF-AZ106MB.

Which bathroom layouts should pick a larger blower than Anzzi EF-AZ106MB?

Do not force Anzzi EF-AZ106MB into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Anzzi EF-AZ106MB retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Anzzi EF-AZ106MB produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Anzzi EF-AZ106MB disturb adjacent bedrooms during night use?

Acoustic measurement places Anzzi EF-AZ106MB at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Anzzi EF-AZ106MB continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Anzzi EF-AZ106MB draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Anzzi EF-AZ106MB pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ106MB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Anzzi EF-AZ106MB?

Anzzi EF-AZ106MB features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Anzzi EF-AZ106MB's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ106MB's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Anzzi EF-AZ106MB code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Anzzi EF-AZ106MB clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)