Rated for 100 CFM open-air (92.8 CFM at 0.25 in. w.g.), Anzzi EF-AZ106MB registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 92 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ106MB Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 92.8 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 92.8% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Anzzi EF-AZ106MB vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 92.8 CFM out of 100 CFM (92.8% retention, 5.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3442050 verifies EF-AZ106MB (series: EF) under Anzzi (8 listed models, qualified 2024-04-19). Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Fantech SMPL100 (484302) (100.0 CFM) and Fantech SMPL100L (484303) (100.0 CFM).
How does Anzzi EF-AZ106MB acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Anzzi EF-AZ106MB (1.5 sones).
How do flex elbows choke Anzzi EF-AZ106MB at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Anzzi EF-AZ106MB moving full rated CFM.
Does Anzzi EF-AZ106MB meet residential exhaust fan code specs?
Inspect Anzzi EF-AZ106MB mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Anzzi (8 models) | ENERGY STAR Certified Partner |
| Model Number & Series | EF-AZ106MB / EF | PD ID 3442050 (Qualified 2024-04-19) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (92.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Anzzi EF-AZ106MB airflow output?
Annual electricity figures and room square-footage ceilings below reflect Anzzi EF-AZ106MB tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 82 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
Which competing models share Anzzi EF-AZ106MB airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Fantech SMPL100 (484302) | 100 / 91.2 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Fantech SMPL100L (484303) | 100 / 91.2 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Hunter 90064A | 100 / 89.6 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Hunter 90065A | 100 / 89.6 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| ACIQ AES100 | 100 / 90.2 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
How much airflow margin does Anzzi EF-AZ106MB give your bath?
Run a quick local room-volume check for Anzzi EF-AZ106MB by entering square footage and ceiling height to spot under-vented steam risks early.
When does Anzzi EF-AZ106MB fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Anzzi EF-AZ106MB.
Limitations & Who Should Skip
- Steam or walk-in tub room > 42 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 92 sq ft with 8-ft ceilings (82 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Anzzi EF-AZ106MB?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Anzzi EF-AZ106MB.
Which bathroom layouts should pick a larger blower than Anzzi EF-AZ106MB?
Do not force Anzzi EF-AZ106MB into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Anzzi EF-AZ106MB retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Anzzi EF-AZ106MB produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Anzzi EF-AZ106MB disturb adjacent bedrooms during night use?
Acoustic measurement places Anzzi EF-AZ106MB at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Anzzi EF-AZ106MB continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Anzzi EF-AZ106MB draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Anzzi EF-AZ106MB pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ106MB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Anzzi EF-AZ106MB?
Anzzi EF-AZ106MB features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Anzzi EF-AZ106MB's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ106MB's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Anzzi EF-AZ106MB code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Anzzi EF-AZ106MB clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)