Skip to main content
Grant Estimator

CFM TF100N Exhaust Fan Specifications

ENERGY STAR PD #2384050 · Bathroom/Utility Room · Qualified 2021-08-13
Verified Specification Summary

Rated for 100 CFM open-air (90.2 CFM at 0.25 in. w.g.), CFM TF100N registers #412 of 607 in quietness (1.5 sones) and delivers 4.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 90 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside CFM TF100N Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 90.2 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
90.2% @ 0.25"
Motor Draw
23.8 W (8.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does CFM TF100N vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 90.2 CFM out of 100 CFM (90.2% retention, 2.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places TF100N (series: TF) (PD #2384050) among 4 CFM entries qualified through 2021-08-13. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.8 watts, about 8.7 kWh/yr (~$1.39/yr at $0.16/kWh) for 1 hr/day shower timers or 208.5 kWh/yr (~$33.36/yr) continuously. Closest competing matches include ACIQ AES100 (100.0 CFM) and S&P PCLP100XP (100.0 CFM).

How does CFM TF100N acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against CFM TF100N (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke CFM TF100N at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps CFM TF100N moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does CFM TF100N meet residential exhaust fan code specs?

Inspect CFM TF100N mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share CFM (4 models) ENERGY STAR Certified Partner
Model Number & Series TF100N / TF PD ID 2384050 (Qualified 2021-08-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (90.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match CFM TF100N airflow output?

Annual electricity figures and room square-footage ceilings below reflect CFM TF100N tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for CFM TF100N
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 90 sq ft1 CFM/sq ft @ 90.2 CFM
Tall Bath (9-ft Ceiling)Up to 80 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 40 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.7 kWh/yr (~$1.39/yr)23.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2208.5 kWh/yr (~$33.36/yr)23.8 W x 8,760 hrs / 1,000

Which competing models share CFM TF100N airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AES100 100 / 90.2 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
S&P PCLP100XP 100 / 90.2 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Anzzi EF-AZ106MB 100 / 92.8 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Anzzi EF-AZ106WH 100 / 92.8 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Fantech SMPL100 (484302) 100 / 91.2 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter

How much airflow margin does CFM TF100N give your bath?

Run a quick local room-volume check for CFM TF100N by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip CFM TF100N on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for CFM TF100N carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 40 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 90 sq ft with 8-ft ceilings (80 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about CFM TF100N?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to CFM TF100N.

How much power does CFM TF100N consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, CFM TF100N draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can CFM TF100N pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from CFM TF100N's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing CFM TF100N?

CFM TF100N features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change CFM TF100N's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing CFM TF100N's safe coverage footprint from 50 sq ft to 44 sq ft.

How does CFM TF100N score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), CFM TF100N delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify CFM TF100N?

Rule out CFM TF100N when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke CFM TF100N capacity?

Because static drag at 0.25 in. w.g. lowers CFM TF100N from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is CFM TF100N compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, CFM TF100N produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories