Certified by EPA ENERGY STAR, Fantech SMPL100 (484302) delivers 100 CFM free-air (91.2 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 91 sq ft (8-ft height) or 81 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SMPL100 (484302) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 91.2 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 91.2% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Fantech SMPL100 (484302) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 91.2 CFM out of 100 CFM (91.2% retention, 3.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Fantech registers 52 certified models, with SKU SMPL100 (484302) (series: bathfan Simple) (PD #2507836) certified since 2023-05-19. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Anzzi EF-AZ106MB (100.0 CFM) and Anzzi EF-AZ106WH (100.0 CFM).
How noisy is Fantech SMPL100 (484302) compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Fantech SMPL100 (484302) measures 1.5 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Fantech SMPL100 (484302) airflow?
Connecting Fantech SMPL100 (484302) through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Fantech SMPL100 (484302) performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech SMPL100 (484302) lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SMPL100 (484302) / bathfan Simple | PD ID 2507836 (Qualified 2023-05-19) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (91.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Fantech SMPL100 (484302)?
Calculated coverage metrics translate Fantech SMPL100 (484302) airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 91 sq ft | 1 CFM/sq ft @ 91.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 41 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Fantech SMPL100 (484302)?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Anzzi EF-AZ106MB | 100 / 92.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Anzzi EF-AZ106WH | 100 / 92.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Hunter 90064A | 100 / 89.6 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Hunter 90065A | 100 / 89.6 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| ACIQ AES100 | 100 / 90.2 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
Does Fantech SMPL100 (484302) match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech SMPL100 (484302) percentage capacity without sending data.
Who should not install Fantech SMPL100 (484302) in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Fantech SMPL100 (484302) for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 41 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 91.2 CFM net static output
- Primary match: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Fantech SMPL100 (484302)?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech SMPL100 (484302).
When is Fantech SMPL100 (484302) undersized or poorly matched for a bath renovation?
Skip Fantech SMPL100 (484302) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Fantech SMPL100 (484302) CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Fantech SMPL100 (484302) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Fantech SMPL100 (484302) sound output compare to noisy contractor-grade fans?
Rated at 1.5 sones, Fantech SMPL100 (484302) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Fantech SMPL100 (484302)?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Fantech SMPL100 (484302) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SMPL100 (484302)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech SMPL100 (484302)?
Fantech SMPL100 (484302) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech SMPL100 (484302)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SMPL100 (484302)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Fantech SMPL100 (484302) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Fantech SMPL100 (484302) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)