The Utilitech 7115-02-CH (Utilitech) moves 100 CFM at 0.1 in. w.g. (84.9 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 7.8 CFM/W efficacy, sizing bathrooms up to 84 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7115-02-CH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 84.9 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 7.8 CFM/W (#365/1,145)
- Static Retention
- 84.9% @ 0.25"
- Motor Draw
- 12.8 W (4.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Utilitech 7115-02-CH vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.9 CFM at 0.25 in. w.g. (84.9% retention, 2.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Utilitech's 22-unit lineup, 7115-02-CH (series: Utilitech) carries PD #2406849 dating to 2023-01-13. Lighting kit: Yes. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.8 watts, about 4.7 kWh/yr (~$0.75/yr at $0.16/kWh) for 1 hr/day shower timers or 112.1 kWh/yr (~$17.94/yr) continuously. Closest competing matches include Delta ITG100ELED (100.0 CFM) and Delta ITG100RLED (100.0 CFM).
Where does Utilitech 7115-02-CH sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.
How does duct geometry alter Utilitech 7115-02-CH static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Utilitech 7115-02-CH?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Utilitech 7115-02-CH alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Utilitech (22 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7115-02-CH / Utilitech | PD ID 2406849 (Qualified 2023-01-13) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (84.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Utilitech 7115-02-CH ventilate safely?
Sizing outputs below convert Utilitech 7115-02-CH tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.7 kWh/yr (~$0.75/yr) | 12.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 112.1 kWh/yr (~$17.94/yr) | 12.8 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Utilitech 7115-02-CH closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100RLED | 100 / 89.9 CFM | 1.5 sones (Same) | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100 | 100 / 88 CFM | 1.5 sones (Same) | 7.6 CFM/W | 4 in. diameter |
| Delta 100LED | 100 / 75 CFM | 1.5 sones (Same) | 7.4 CFM/W | 4 in. diameter |
| Delta GBR100LED | 100 / 75 CFM | 1.5 sones (Same) | 7.4 CFM/W | 4 in. diameter |
Will Utilitech 7115-02-CH clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Utilitech 7115-02-CH satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does Utilitech 7115-02-CH suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Utilitech 7115-02-CH for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 34 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 84 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Utilitech 7115-02-CH?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Utilitech 7115-02-CH.
How many kWh per year does Utilitech 7115-02-CH add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Utilitech 7115-02-CH averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Utilitech 7115-02-CH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7115-02-CH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Utilitech 7115-02-CH?
Utilitech 7115-02-CH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Utilitech 7115-02-CH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7115-02-CH's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Utilitech 7115-02-CH pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7115-02-CH easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Utilitech 7115-02-CH in a bathroom remodel?
Avoid specifying Utilitech 7115-02-CH in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Utilitech 7115-02-CH airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Utilitech 7115-02-CH achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Utilitech 7115-02-CH occupy in EPA filings?
With 1.5 sones at 0.1 in. w.g., Utilitech 7115-02-CH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)