Skip to main content
Grant Estimator

Utilitech 7115-01 Exhaust Fan Specifications

ENERGY STAR PD #2343313 · Bathroom/Utility Room · Qualified 2017-04-21
Verified Specification Summary

The Utilitech 7115-01 (Utilitech) moves 100 CFM at 0.1 in. w.g. (95.4 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 6.5 CFM/W efficacy, sizing bathrooms up to 95 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7115-01 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 95.4 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
6.5 CFM/W (#436/1,145)
Static Retention
95.4% @ 0.25"
Motor Draw
15.4 W (5.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Utilitech 7115-01 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.4 CFM out of 100 CFM (95.4% retention, 7.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Utilitech 7115-01 (series: Utilitech) under PD #2343313 (22 models registered, 2017-04-21). Lighting kit: No. At 6.5 CFM/W (#436 of 1,145, top 38.2% of 1,145 rated models, more efficient than 61.8% of rated models, 1.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.4 watts, about 5.6 kWh/yr (~$0.90/yr at $0.16/kWh) for 1 hr/day shower timers or 134.9 kWh/yr (~$21.58/yr) continuously. Closest competing matches include Delta 100LED (100.0 CFM) and Delta GBR100LED (100.0 CFM).

Where does Utilitech 7115-01 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How does duct geometry alter Utilitech 7115-01 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Utilitech 7115-01?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Utilitech 7115-01 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Utilitech (22 models) ENERGY STAR Certified Partner
Model Number & Series 7115-01 / Utilitech PD ID 2343313 (Qualified 2017-04-21)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (95.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Utilitech 7115-01 ventilate safely?

Sizing outputs below convert Utilitech 7115-01 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Utilitech 7115-01
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 95 sq ft1 CFM/sq ft @ 95.4 CFM
Tall Bath (9-ft Ceiling)Up to 84 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 45 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.6 kWh/yr (~$0.90/yr)15.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2134.9 kWh/yr (~$21.58/yr)15.4 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Utilitech 7115-01 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta 100LED 100 / 75 CFM 1.5 sones (Same) 7.4 CFM/W 4 in. diameter
Delta GBR100LED 100 / 75 CFM 1.5 sones (Same) 7.4 CFM/W 4 in. diameter
Delta ITG100 100 / 88 CFM 1.5 sones (Same) 7.6 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter

Will Utilitech 7115-01 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Utilitech 7115-01 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Does Utilitech 7115-01 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Utilitech 7115-01 for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 45 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 95 sq ft with 8-ft ceilings (84 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Utilitech 7115-01?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Utilitech 7115-01.

How many kWh per year does Utilitech 7115-01 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Utilitech 7115-01 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Utilitech 7115-01 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7115-01's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Utilitech 7115-01?

Utilitech 7115-01 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Utilitech 7115-01's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7115-01's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Utilitech 7115-01 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7115-01 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Utilitech 7115-01 in a bathroom remodel?

Avoid specifying Utilitech 7115-01 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Utilitech 7115-01 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Utilitech 7115-01 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Utilitech 7115-01 occupy in EPA filings?

With 1.5 sones at 0.1 in. w.g., Utilitech 7115-01 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories