Certified by EPA ENERGY STAR, Loren Cook Company GC-242 delivers 142 CFM free-air (112 CFM at 0.25 in. w.g.) and registers #518 of 607 in quietness (1.7 sones) and delivers 5.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 112 sq ft (8-ft height) or 99 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Loren Cook Company GC-242 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 142 / 112 CFM
- Noise @ 0.1"
- 1.7 sones (#518/607)
- Efficacy Rank
- 5.3 CFM/W (#494/1,145)
- Static Retention
- 78.9% @ 0.25"
- Motor Draw
- 26.8 W (9.8 kWh/yr)
- Duct & Tier
- 4.5 x 6 in. rectangular · Standard

What does Loren Cook Company GC-242 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.7 sones (#518 of 607 rated models, 0.70 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 142 CFM open-air to 112 CFM at 0.25 in. w.g. (78.9% retention, 8.8 pts lower retention than the 87.7% median), making smooth 4.5 x 6 in. rectangular rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Loren Cook Company's 5-unit lineup, GC-242 (series: Gemini, Model GC, 200-900 Series Ceiling and Wall Blowers) carries PD #2250174 dating to 2014-11-27. Lighting kit: No. At 5.3 CFM/W (#494 of 1,145, top 43.5% of 1,145 rated models, more efficient than 56.5% of rated models, 0.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).
How noisy is Loren Cook Company GC-242 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Loren Cook Company GC-242 measures 1.7 sones across the 1,145-model registry.
Why does rigid 4.5 x 6 in. rectangular ducting protect Loren Cook Company GC-242 airflow?
Connecting Loren Cook Company GC-242 through rigid 4.5 x 6 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Loren Cook Company GC-242 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Loren Cook Company GC-242 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Loren Cook Company (5 models) | ENERGY STAR Certified Partner |
| Model Number & Series | GC-242 / Gemini, Model GC, 200-900 Series Ceiling and Wall Blowers | PD ID 2250174 (Qualified 2014-11-27) |
| Duct Connection | 4.5 x 6 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (112 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Loren Cook Company GC-242?
Calculated coverage metrics translate Loren Cook Company GC-242 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.8 kWh/yr (~$1.57/yr) | 26.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 234.8 kWh/yr (~$37.57/yr) | 26.8 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Loren Cook Company GC-242?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones (-0.20) | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones (-0.20) | 4.5 CFM/W | 6 in. diameter |
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones (-0.20) | 4.7 CFM/W | 6 in. diameter |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones (-0.20) | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones (-0.20) | 4.5 CFM/W | 6 in. diameter |
Does Loren Cook Company GC-242 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Loren Cook Company GC-242 percentage capacity without sending data.
Where should contractors skip Loren Cook Company GC-242 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Loren Cook Company GC-242 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 62 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 112 CFM net static output
- Works well for: Collar pairs with 4.5 x 6 in. rectangular duct straight outdoors
Which homeowner questions come up most for Loren Cook Company GC-242?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Loren Cook Company GC-242.
Will long attic ducting choke Loren Cook Company GC-242 capacity?
Because static drag at 0.25 in. w.g. lowers Loren Cook Company GC-242 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4.5 x 6 in. rectangular rigid ducting straight to a dedicated exterior damper.
How loud is Loren Cook Company GC-242 compared with a standard 3.0 sone builder fan?
Tested at 1.7 sones, Loren Cook Company GC-242 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Loren Cook Company GC-242 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Loren Cook Company GC-242 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Loren Cook Company GC-242 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Loren Cook Company GC-242's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Loren Cook Company GC-242?
Loren Cook Company GC-242 features a 4.5 x 6 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Loren Cook Company GC-242's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Loren Cook Company GC-242's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Loren Cook Company GC-242 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Loren Cook Company GC-242 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Loren Cook Company GC-242?
Rule out Loren Cook Company GC-242 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)