Skip to main content
Grant Estimator

Broan QT130LE Exhaust Fan Specifications

ENERGY STAR PD #2404744 · Bathroom/Utility Room · Qualified 2022-11-18
Verified Specification Summary

Rated for 130 CFM open-air (126.1 CFM at 0.25 in. w.g.), Broan QT130LE registers #412 of 607 in quietness (1.5 sones) and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 126 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QT130LE Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / 126.1 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.5 CFM/W (#632/1,145)
Static Retention
97.0% @ 0.25"
Motor Draw
28.9 W (10.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan QT130LE vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 126.1 CFM out of 130 CFM (97.0% retention, 9.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU QT130LE (series: QT SERIES) (PD #2404744) certified since 2022-11-18. Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.9 watts, about 10.5 kWh/yr (~$1.68/yr at $0.16/kWh) for 1 hr/day shower timers or 253.2 kWh/yr (~$40.51/yr) continuously. Closest competing matches include Nutone QTN130LE1 (130.0 CFM) and Greenheck SP-B110ES (118.0 CFM).

How does Broan QT130LE acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan QT130LE (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke Broan QT130LE at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan QT130LE moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan QT130LE meet residential exhaust fan code specs?

Inspect Broan QT130LE mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series QT130LE / QT SERIES PD ID 2404744 (Qualified 2022-11-18)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (126.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Broan QT130LE airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan QT130LE tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan QT130LE
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 126 sq ft1 CFM/sq ft @ 126.1 CFM
Tall Bath (9-ft Ceiling)Up to 112 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 76 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.5 kWh/yr (~$1.68/yr)28.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2253.2 kWh/yr (~$40.51/yr)28.9 W x 8,760 hrs / 1,000

Which competing models share Broan QT130LE airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones (Same) 4.5 CFM/W 6 in. diameter
Greenheck SP-B110ES 118 / 100 CFM 1.5 sones (Same) 4.0 CFM/W 6 in. diameter
KORA SBF110N 119.2 / N/A CFM 1.6 sones (+0.10) 3.5 CFM/W 4 in. diameter
Broan QT130E 130 / 130.4 CFM 1.5 sones (Same) 4.7 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones (+0.20) 5.3 CFM/W 4.5 x 6 in. rectangular

How much airflow margin does Broan QT130LE give your bath?

Run a quick local room-volume check for Broan QT130LE by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Broan QT130LE?

Match Broan QT130LE directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 76 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 126 sq ft with 8-ft ceilings (112 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about Broan QT130LE?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan QT130LE.

Where does Broan QT130LE run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan QT130LE.

What happens to Broan QT130LE CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan QT130LE moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does Broan QT130LE sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Broan QT130LE produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Broan QT130LE cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan QT130LE 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Broan QT130LE pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QT130LE's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan QT130LE?

Broan QT130LE features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan QT130LE's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QT130LE's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Broan QT130LE ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan QT130LE covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories