The Air King AK90 (N/A) moves 90 CFM at 0.1 in. w.g. (75.8 CFM at 0.25 in. w.g.), registers #516 of 607 in quietness (1.6 sones), and delivers 3.7 CFM/W efficacy, sizing bathrooms up to 75 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK90 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 75.8 CFM
- Noise @ 0.1"
- 1.6 sones (#516/607)
- Efficacy Rank
- 3.7 CFM/W (#987/1,145)
- Static Retention
- 84.2% @ 0.25"
- Motor Draw
- 24.3 W (8.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Air King AK90 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.6 sones (#516 of 607 rated models, 0.60 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 90 CFM open-air to 75.8 CFM at 0.25 in. w.g. (84.2% retention, 3.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places AK90 (series: N/A) (PD #2250896) among 62 Air King entries qualified through 2015-10-01. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.3 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 212.9 kWh/yr (~$34.06/yr) continuously. Closest competing matches include Home Netwerks 7105-09-BN (90.0 CFM) and HomeWerks Worldwide 7105-09-MB (90.0 CFM).
Where does Air King AK90 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.6 sones against all 1,145 EPA listings.
How does duct geometry alter Air King AK90 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Air King AK90?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Air King AK90 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK90 / N/A | PD ID 2250896 (Qualified 2015-10-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (75.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.6 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Air King AK90 ventilate safely?
Sizing outputs below convert Air King AK90 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 75 sq ft | 1 CFM/sq ft @ 75.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 67 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 25 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 212.9 kWh/yr (~$34.06/yr) | 24.3 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Air King AK90 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Home Netwerks 7105-09-BN | 90 / 72.6 CFM | 1.5 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7105-09-MB | 90 / 72.6 CFM | 1.5 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
| Utilitech 7105-09-L | 90 / 72.6 CFM | 1.5 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-11 | 90 / 82 CFM | 1.5 sones (-0.10) | 4.0 CFM/W | 4 in. diameter |
| Akicon AK1390N1-W/B/S | 90 / 67.4 CFM | 1.5 sones (-0.10) | 4.1 CFM/W | 4 in. diameter |
Will Air King AK90 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Air King AK90 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Where should contractors skip Air King AK90 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Air King AK90 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 25 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 75 sq ft with 8-ft ceilings (67 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Air King AK90?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Air King AK90.
Will long attic ducting choke Air King AK90 capacity?
Because static drag at 0.25 in. w.g. lowers Air King AK90 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Air King AK90 compared with a standard 3.0 sone builder fan?
Tested at 1.6 sones, Air King AK90 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Air King AK90 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Air King AK90 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Air King AK90 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK90's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King AK90?
Air King AK90 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King AK90's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK90's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Air King AK90 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Air King AK90 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Air King AK90?
Rule out Air King AK90 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)