Skip to main content
Grant Estimator

Akicon AK1390N1-W/B/S Exhaust Fan Specifications

ENERGY STAR PD #2920622 · Bathroom/Utility Room · Qualified 2023-12-15
Verified Specification Summary

Certified by EPA ENERGY STAR, Akicon AK1390N1-W/B/S delivers 90 CFM free-air (67.4 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 67 sq ft (8-ft height) or 59 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK1390N1-W/B/S Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 67.4 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
74.9% @ 0.25"
Motor Draw
22.0 W (8.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Akicon AK1390N1-W/B/S vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 67.4 CFM at 0.25 in. w.g. (74.9% retention, 12.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places AK1390N1-W/B/S (series: AK1390N1-W/B/S) (PD #2920622) among 14 Akicon entries qualified through 2023-12-15. Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.0 watts, about 8.0 kWh/yr (~$1.28/yr at $0.16/kWh) for 1 hr/day shower timers or 192.7 kWh/yr (~$30.83/yr) continuously. Closest competing matches include Tech Drive TD-BF-11 (90.0 CFM) and Ortech ODE-9010 (90.0 CFM).

How noisy is Akicon AK1390N1-W/B/S compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Akicon AK1390N1-W/B/S measures 1.5 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why does rigid 4 in. diameter ducting protect Akicon AK1390N1-W/B/S airflow?

Connecting Akicon AK1390N1-W/B/S through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Akicon AK1390N1-W/B/S performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Akicon AK1390N1-W/B/S lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Akicon (14 models) ENERGY STAR Certified Partner
Model Number & Series AK1390N1-W/B/S / AK1390N1-W/B/S PD ID 2920622 (Qualified 2023-12-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (67.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Akicon AK1390N1-W/B/S?

Calculated coverage metrics translate Akicon AK1390N1-W/B/S airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Akicon AK1390N1-W/B/S
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 67 sq ft1 CFM/sq ft @ 67.4 CFM
Tall Bath (9-ft Ceiling)Up to 59 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.0 kWh/yr (~$1.28/yr)22.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2192.7 kWh/yr (~$30.83/yr)22.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Akicon AK1390N1-W/B/S?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-11 90 / 82 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Ortech ODE-9010 90 / 81.3 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-V80A 90 / 79.2 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Air King FR90 90 / 73.2 CFM 1.5 sones (Same) 3.7 CFM/W 4 in. diameter
Home Netwerks 7105-09-BN 90 / 72.6 CFM 1.5 sones (Same) 3.6 CFM/W 4 in. diameter

Does Akicon AK1390N1-W/B/S match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Akicon AK1390N1-W/B/S percentage capacity without sending data.

What plumbing or duct constraints rule out Akicon AK1390N1-W/B/S?

Compare where Akicon AK1390N1-W/B/S excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 67.4 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Akicon AK1390N1-W/B/S?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Akicon AK1390N1-W/B/S.

How does Akicon AK1390N1-W/B/S handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Akicon AK1390N1-W/B/S yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Akicon AK1390N1-W/B/S quiet enough for a primary bedroom bathroom?

At 1.5 sones, Akicon AK1390N1-W/B/S produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Akicon AK1390N1-W/B/S energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Akicon AK1390N1-W/B/S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK1390N1-W/B/S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Akicon AK1390N1-W/B/S?

Akicon AK1390N1-W/B/S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Akicon AK1390N1-W/B/S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK1390N1-W/B/S's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Akicon AK1390N1-W/B/S serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Akicon AK1390N1-W/B/S supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Akicon AK1390N1-W/B/S for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Akicon AK1390N1-W/B/S lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories