Akicon AK1390N2-S Exhaust Fan Specifications

ENERGY STAR PD #4008353 · Bathroom/Utility Room · Qualified 2025-03-28
Verified Specification Summary

Tested under HVI protocols, the Akicon AK1390N2-S exhaust unit achieves 90 CFM at 0.1 in. w.g. (71.7 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 71 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK1390N2-S Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 71.7 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
79.7% @ 0.25"
Motor Draw
21.4 W (7.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Akicon AK1390N2-S vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 71.7 CFM at 0.25 in. w.g. (79.7% retention, 8.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Akicon's 14-unit lineup, AK1390N2-S (series: AK1390N2-S) carries PD #4008353 dating to 2025-03-28. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Ortech ODE-9010 (90.0 CFM) and Panasonic Eco Solutions RG-V80A (90.0 CFM).

Where do Akicon AK1390N2-S sones rank across EPA ENERGY STAR fans?

Comparing Akicon AK1390N2-S (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

What attic duct routing preserves Akicon AK1390N2-S CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Akicon AK1390N2-S, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Akicon AK1390N2-S measure up on airflow and noise ratings?

Each row below breaks down Akicon AK1390N2-S certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Akicon (14 models) ENERGY STAR Certified Partner
Model Number & Series AK1390N2-S / AK1390N2-S PD ID 4008353 (Qualified 2025-03-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (71.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Akicon AK1390N2-S CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Akicon AK1390N2-S
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 71 sq ft1 CFM/sq ft @ 71.7 CFM
Tall Bath (9-ft Ceiling)Up to 63 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 21 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.8 kWh/yr (~$1.25/yr)21.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2187.5 kWh/yr (~$30.00/yr)21.4 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Akicon AK1390N2-S?

Compare Akicon AK1390N2-S side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Ortech ODE-9010 90 / 81.3 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-V80A 90 / 79.2 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Tech Drive TD-BF-11 90 / 82 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Air King FR90 90 / 73.2 CFM 1.5 sones (Same) 3.7 CFM/W 4 in. diameter
Home Netwerks 7105-09-BN 90 / 72.6 CFM 1.5 sones (Same) 3.6 CFM/W 4 in. diameter

Can you size Akicon AK1390N2-S for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Akicon AK1390N2-S verified capacity.

When does Akicon AK1390N2-S fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Akicon AK1390N2-S.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 71.7 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 1.5 sones up to 71 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Akicon AK1390N2-S?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Akicon AK1390N2-S.

Will Akicon AK1390N2-S disturb adjacent bedrooms during night use?

Acoustic measurement places Akicon AK1390N2-S at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Akicon AK1390N2-S continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Akicon AK1390N2-S draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Akicon AK1390N2-S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK1390N2-S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Akicon AK1390N2-S?

Akicon AK1390N2-S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Akicon AK1390N2-S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK1390N2-S's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Akicon AK1390N2-S code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Akicon AK1390N2-S clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Akicon AK1390N2-S?

Do not force Akicon AK1390N2-S into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Akicon AK1390N2-S retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Akicon AK1390N2-S produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.