Tested under HVI protocols, the Akicon AK1390N2-S exhaust unit achieves 90 CFM at 0.1 in. w.g. (71.7 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 71 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK1390N2-S Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 71.7 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 79.7% @ 0.25"
- Motor Draw
- 21.4 W (7.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Akicon AK1390N2-S vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 90 CFM open-air to 71.7 CFM at 0.25 in. w.g. (79.7% retention, 8.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Akicon's 14-unit lineup, AK1390N2-S (series: AK1390N2-S) carries PD #4008353 dating to 2025-03-28. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Ortech ODE-9010 (90.0 CFM) and Panasonic Eco Solutions RG-V80A (90.0 CFM).
Where do Akicon AK1390N2-S sones rank across EPA ENERGY STAR fans?
Comparing Akicon AK1390N2-S (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Akicon AK1390N2-S CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Akicon AK1390N2-S, preventing premature peeling paint and mold growth.
How does Akicon AK1390N2-S measure up on airflow and noise ratings?
Each row below breaks down Akicon AK1390N2-S certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Akicon (14 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK1390N2-S / AK1390N2-S | PD ID 4008353 (Qualified 2025-03-28) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (71.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Akicon AK1390N2-S CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.8 kWh/yr (~$1.25/yr) | 21.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 187.5 kWh/yr (~$30.00/yr) | 21.4 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Akicon AK1390N2-S?
Compare Akicon AK1390N2-S side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Ortech ODE-9010 | 90 / 81.3 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-V80A | 90 / 79.2 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-11 | 90 / 82 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Air King FR90 | 90 / 73.2 CFM | 1.5 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Home Netwerks 7105-09-BN | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
Can you size Akicon AK1390N2-S for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Akicon AK1390N2-S verified capacity.
When does Akicon AK1390N2-S fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Akicon AK1390N2-S.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 71.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 1.5 sones up to 71 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Akicon AK1390N2-S?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Akicon AK1390N2-S.
Will Akicon AK1390N2-S disturb adjacent bedrooms during night use?
Acoustic measurement places Akicon AK1390N2-S at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Akicon AK1390N2-S continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Akicon AK1390N2-S draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Akicon AK1390N2-S pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK1390N2-S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Akicon AK1390N2-S?
Akicon AK1390N2-S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Akicon AK1390N2-S's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK1390N2-S's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Akicon AK1390N2-S code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Akicon AK1390N2-S clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Akicon AK1390N2-S?
Do not force Akicon AK1390N2-S into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Akicon AK1390N2-S retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Akicon AK1390N2-S produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)