The Akicon AK1390N2-W (AK1390N2-W) moves 90 CFM at 0.1 in. w.g. (71.7 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.2 CFM/W efficacy, sizing bathrooms up to 71 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK1390N2-W Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 71.7 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 79.7% @ 0.25"
- Motor Draw
- 21.4 W (7.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Akicon AK1390N2-W vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 90 CFM open-air to 71.7 CFM at 0.25 in. w.g. (79.7% retention, 8.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places AK1390N2-W (series: AK1390N2-W) (PD #4008354) among 14 Akicon entries qualified through 2025-03-28. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Ortech ODE-9010 (90.0 CFM) and Panasonic Eco Solutions RG-V80A (90.0 CFM).
Where does Akicon AK1390N2-W sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.
How does duct geometry alter Akicon AK1390N2-W static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Akicon AK1390N2-W?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Akicon AK1390N2-W alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Akicon (14 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK1390N2-W / AK1390N2-W | PD ID 4008354 (Qualified 2025-03-28) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (71.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Akicon AK1390N2-W ventilate safely?
Sizing outputs below convert Akicon AK1390N2-W tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.8 kWh/yr (~$1.25/yr) | 21.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 187.5 kWh/yr (~$30.00/yr) | 21.4 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Akicon AK1390N2-W closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Ortech ODE-9010 | 90 / 81.3 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-V80A | 90 / 79.2 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-11 | 90 / 82 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Air King FR90 | 90 / 73.2 CFM | 1.5 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Home Netwerks 7105-09-BN | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
Will Akicon AK1390N2-W clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Akicon AK1390N2-W satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Which bath layouts should avoid specifying Akicon AK1390N2-W?
Match Akicon AK1390N2-W directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 21 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 71 sq ft with 8-ft ceilings (63 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Akicon AK1390N2-W?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Akicon AK1390N2-W.
What bathroom square footage can Akicon AK1390N2-W ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Akicon AK1390N2-W covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Akicon AK1390N2-W run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Akicon AK1390N2-W.
What happens to Akicon AK1390N2-W CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Akicon AK1390N2-W moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Akicon AK1390N2-W sit on acoustic comfort for senior homeowners?
Measuring 1.5 sones, Akicon AK1390N2-W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Akicon AK1390N2-W cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Akicon AK1390N2-W 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Akicon AK1390N2-W pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK1390N2-W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Akicon AK1390N2-W?
Akicon AK1390N2-W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Akicon AK1390N2-W's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK1390N2-W's safe coverage footprint from 50 sq ft to 44 sq ft.