Akicon AK1390N3-W/B/S Exhaust Fan Specifications

ENERGY STAR PD #2920621 · Bathroom/Utility Room · Qualified 2023-12-15
Verified Specification Summary

In EPA dataset 8dv7-nngq, Akicon AK1390N3-W/B/S tests at 90 CFM free discharge (71.8 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 71 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK1390N3-W/B/S Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 71.8 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
79.8% @ 0.25"
Motor Draw
21.4 W (7.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Akicon AK1390N3-W/B/S vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 71.8 CFM at 0.25 in. w.g. (79.8% retention, 7.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Akicon's 14-unit lineup, AK1390N3-W/B/S (series: AK1390N3-W/B/S) carries PD #2920621 dating to 2023-12-15. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Ortech ODE-9010 (90.0 CFM) and Panasonic Eco Solutions RG-V80A (90.0 CFM).

Does Akicon AK1390N3-W/B/S fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Akicon AK1390N3-W/B/S at 1.5 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why avoid unvented attic termination with Akicon AK1390N3-W/B/S?

Under ASHRAE 62.2 best practice, Akicon AK1390N3-W/B/S needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Akicon AK1390N3-W/B/S?

Before cutting ceiling drywall or sizing attic transitions for Akicon AK1390N3-W/B/S, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Akicon (14 models) ENERGY STAR Certified Partner
Model Number & Series AK1390N3-W/B/S / AK1390N3-W/B/S PD ID 2920621 (Qualified 2023-12-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (71.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Akicon AK1390N3-W/B/S?

Bathroom ventilation sizing below maps Akicon AK1390N3-W/B/S motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Akicon AK1390N3-W/B/S
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 71 sq ft1 CFM/sq ft @ 71.8 CFM
Tall Bath (9-ft Ceiling)Up to 63 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 21 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.8 kWh/yr (~$1.25/yr)21.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2187.5 kWh/yr (~$30.00/yr)21.4 W x 8,760 hrs / 1,000

What peer models sit nearest Akicon AK1390N3-W/B/S in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Akicon AK1390N3-W/B/S.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Ortech ODE-9010 90 / 81.3 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-V80A 90 / 79.2 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Tech Drive TD-BF-11 90 / 82 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Air King FR90 90 / 73.2 CFM 1.5 sones (Same) 3.7 CFM/W 4 in. diameter
Home Netwerks 7105-09-BN 90 / 72.6 CFM 1.5 sones (Same) 3.6 CFM/W 4 in. diameter

What percentage of room demand does Akicon AK1390N3-W/B/S cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Akicon AK1390N3-W/B/S tested delivery.

Who should not install Akicon AK1390N3-W/B/S in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Akicon AK1390N3-W/B/S for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 71.8 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 1.5 sones up to 71 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Akicon AK1390N3-W/B/S?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Akicon AK1390N3-W/B/S.

How does Akicon AK1390N3-W/B/S sound output compare to noisy contractor-grade fans?

Rated at 1.5 sones, Akicon AK1390N3-W/B/S produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Akicon AK1390N3-W/B/S?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Akicon AK1390N3-W/B/S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK1390N3-W/B/S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Akicon AK1390N3-W/B/S?

Akicon AK1390N3-W/B/S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Akicon AK1390N3-W/B/S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK1390N3-W/B/S's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Akicon AK1390N3-W/B/S satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Akicon AK1390N3-W/B/S clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Akicon AK1390N3-W/B/S undersized or poorly matched for a bath renovation?

Skip Akicon AK1390N3-W/B/S if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Akicon AK1390N3-W/B/S CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Akicon AK1390N3-W/B/S registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories