Rated for 90 CFM open-air (72.6 CFM at 0.25 in. w.g.), HomeWerks Worldwide 7105-09-MB registers #412 of 607 in quietness (1.5 sones) and delivers 3.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 72 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7105-09-MB Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 72.6 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 80.7% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does HomeWerks Worldwide 7105-09-MB vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 90 CFM open-air to 72.6 CFM at 0.25 in. w.g. (80.7% retention, 7.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3629331 verifies 7105-09-MB (series: 7105-09-MB) under HomeWerks Worldwide (31 listed models, qualified 2024-05-24). Lighting kit: Yes. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Home Netwerks 7105-09-BN (90.0 CFM) and Utilitech 7105-09-L (90.0 CFM).
How does HomeWerks Worldwide 7105-09-MB acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against HomeWerks Worldwide 7105-09-MB (1.5 sones).
How do flex elbows choke HomeWerks Worldwide 7105-09-MB at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps HomeWerks Worldwide 7105-09-MB moving full rated CFM.
Does HomeWerks Worldwide 7105-09-MB meet residential exhaust fan code specs?
Inspect HomeWerks Worldwide 7105-09-MB mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7105-09-MB / 7105-09-MB | PD ID 3629331 (Qualified 2024-05-24) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (72.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match HomeWerks Worldwide 7105-09-MB airflow output?
Annual electricity figures and room square-footage ceilings below reflect HomeWerks Worldwide 7105-09-MB tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 72 sq ft | 1 CFM/sq ft @ 72.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 64 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 22 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
Which competing models share HomeWerks Worldwide 7105-09-MB airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Home Netwerks 7105-09-BN | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Utilitech 7105-09-L | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Air King FR90 | 90 / 73.2 CFM | 1.5 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-11 | 90 / 82 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Akicon AK1390N1-W/B/S | 90 / 67.4 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
How much airflow margin does HomeWerks Worldwide 7105-09-MB give your bath?
Run a quick local room-volume check for HomeWerks Worldwide 7105-09-MB by entering square footage and ceiling height to spot under-vented steam risks early.
Does HomeWerks Worldwide 7105-09-MB suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying HomeWerks Worldwide 7105-09-MB for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 22 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 72 sq ft with 8-ft ceilings (64 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about HomeWerks Worldwide 7105-09-MB?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to HomeWerks Worldwide 7105-09-MB.
Who should NOT install HomeWerks Worldwide 7105-09-MB in a bathroom remodel?
Avoid specifying HomeWerks Worldwide 7105-09-MB in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut HomeWerks Worldwide 7105-09-MB airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, HomeWerks Worldwide 7105-09-MB achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does HomeWerks Worldwide 7105-09-MB occupy in EPA filings?
With 1.5 sones at 0.1 in. w.g., HomeWerks Worldwide 7105-09-MB produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does HomeWerks Worldwide 7105-09-MB add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, HomeWerks Worldwide 7105-09-MB averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can HomeWerks Worldwide 7105-09-MB pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7105-09-MB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7105-09-MB?
HomeWerks Worldwide 7105-09-MB features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7105-09-MB's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7105-09-MB's safe coverage footprint from 50 sq ft to 44 sq ft.
Does HomeWerks Worldwide 7105-09-MB pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7105-09-MB easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)