Ortech ODE-9010 Exhaust Fan Specifications

ENERGY STAR PD #4510677 · Bathroom/Utility Room · Qualified 2025-10-03
Verified Specification Summary

Certified by EPA ENERGY STAR, Ortech ODE-9010 delivers 90 CFM free-air (81.3 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 81 sq ft (8-ft height) or 72 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODE-9010 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 81.3 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
90.3% @ 0.25"
Motor Draw
21.4 W (7.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODE-9010 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 81.3 CFM out of 90 CFM (90.3% retention, 2.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Ortech registers 27 certified models, with SKU ODE-9010 (series: ODE-9010) (PD #4510677) certified since 2025-10-03. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Akicon AK1390N2-B (90.0 CFM) and Akicon AK1390N2-S (90.0 CFM).

How noisy is Ortech ODE-9010 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODE-9010 measures 1.5 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why does rigid 4 in. diameter ducting protect Ortech ODE-9010 airflow?

Connecting Ortech ODE-9010 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Ortech ODE-9010 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODE-9010 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODE-9010 / ODE-9010 PD ID 4510677 (Qualified 2025-10-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (81.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Ortech ODE-9010?

Calculated coverage metrics translate Ortech ODE-9010 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Ortech ODE-9010
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 81 sq ft1 CFM/sq ft @ 81.3 CFM
Tall Bath (9-ft Ceiling)Up to 72 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 31 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.8 kWh/yr (~$1.25/yr)21.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2187.5 kWh/yr (~$30.00/yr)21.4 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Ortech ODE-9010?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Akicon AK1390N2-B 90 / 71.7 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-S 90 / 71.7 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-W 90 / 71.7 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Akicon AK1390N3-W/B/S 90 / 71.8 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-V80A 90 / 79.2 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter

Does Ortech ODE-9010 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODE-9010 percentage capacity without sending data.

Which bath layouts should avoid specifying Ortech ODE-9010?

Match Ortech ODE-9010 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 31 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 81.3 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Ortech ODE-9010?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODE-9010.

Where does Ortech ODE-9010 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Ortech ODE-9010.

What happens to Ortech ODE-9010 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Ortech ODE-9010 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Ortech ODE-9010 sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Ortech ODE-9010 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Ortech ODE-9010 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Ortech ODE-9010 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Ortech ODE-9010 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODE-9010's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODE-9010?

Ortech ODE-9010 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODE-9010's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODE-9010's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Ortech ODE-9010 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Ortech ODE-9010 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories