Certified by EPA ENERGY STAR, Ortech ODE-9010 delivers 90 CFM free-air (81.3 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 81 sq ft (8-ft height) or 72 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODE-9010 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 81.3 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 90.3% @ 0.25"
- Motor Draw
- 21.4 W (7.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Ortech ODE-9010 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 81.3 CFM out of 90 CFM (90.3% retention, 2.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Ortech registers 27 certified models, with SKU ODE-9010 (series: ODE-9010) (PD #4510677) certified since 2025-10-03. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.4 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 187.5 kWh/yr (~$30.00/yr) continuously. Closest competing matches include Akicon AK1390N2-B (90.0 CFM) and Akicon AK1390N2-S (90.0 CFM).
How noisy is Ortech ODE-9010 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODE-9010 measures 1.5 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Ortech ODE-9010 airflow?
Connecting Ortech ODE-9010 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Ortech ODE-9010 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODE-9010 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ODE-9010 / ODE-9010 | PD ID 4510677 (Qualified 2025-10-03) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (81.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Ortech ODE-9010?
Calculated coverage metrics translate Ortech ODE-9010 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 81 sq ft | 1 CFM/sq ft @ 81.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 72 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 31 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.8 kWh/yr (~$1.25/yr) | 21.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 187.5 kWh/yr (~$30.00/yr) | 21.4 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Ortech ODE-9010?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Akicon AK1390N2-B | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N2-S | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N2-W | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N3-W/B/S | 90 / 71.8 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-V80A | 90 / 79.2 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
Does Ortech ODE-9010 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODE-9010 percentage capacity without sending data.
Which bath layouts should avoid specifying Ortech ODE-9010?
Match Ortech ODE-9010 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 31 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 81.3 CFM net static output
- Optimal use: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Ortech ODE-9010?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODE-9010.
Where does Ortech ODE-9010 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Ortech ODE-9010.
What happens to Ortech ODE-9010 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Ortech ODE-9010 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Ortech ODE-9010 sit on acoustic comfort for senior homeowners?
Measuring 1.5 sones, Ortech ODE-9010 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Ortech ODE-9010 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Ortech ODE-9010 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Ortech ODE-9010 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODE-9010's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech ODE-9010?
Ortech ODE-9010 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech ODE-9010's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODE-9010's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Ortech ODE-9010 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Ortech ODE-9010 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)