Homeowners specifying Panasonic Eco Solutions RG-V80A gain 90 CFM at 0.1 in. w.g. (79.2 CFM at 0.25 in. w.g.) where it registers #412 of 607 in quietness (1.5 sones) and delivers 4.3 CFM/W efficacy, venting bathrooms up to 79 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic Eco Solutions RG-V80A Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 79.2 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 88.0% @ 0.25"
- Motor Draw
- 20.9 W (7.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic Eco Solutions RG-V80A vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79.2 CFM out of 90 CFM (88.0% retention, 0.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2669651 verifies RG-V80A (series: Whisper Vanity) under Panasonic Eco Solutions (9 listed models, qualified 2023-07-21). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.9 watts, about 7.6 kWh/yr (~$1.22/yr at $0.16/kWh) for 1 hr/day shower timers or 183.1 kWh/yr (~$29.30/yr) continuously. Closest competing matches include Akicon AK1390N2-B (90.0 CFM) and Akicon AK1390N2-S (90.0 CFM).
What acoustic percentile does Panasonic Eco Solutions RG-V80A occupy among 1,145 bath blowers?
Inspect how Panasonic Eco Solutions RG-V80A positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Panasonic Eco Solutions RG-V80A best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic Eco Solutions RG-V80A housings.
Where do Panasonic Eco Solutions RG-V80A acoustic and static metrics stand?
Compare Panasonic Eco Solutions RG-V80A published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic Eco Solutions (9 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RG-V80A / Whisper Vanity | PD ID 2669651 (Qualified 2023-07-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (79.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Panasonic Eco Solutions RG-V80A handle taller ceilings or walk-in tub steam?
Evaluate how Panasonic Eco Solutions RG-V80A scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 79 sq ft | 1 CFM/sq ft @ 79.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 29 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.6 kWh/yr (~$1.22/yr) | 20.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 183.1 kWh/yr (~$29.30/yr) | 20.9 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Panasonic Eco Solutions RG-V80A?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Akicon AK1390N2-B | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N2-S | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N2-W | 90 / 71.7 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N3-W/B/S | 90 / 71.8 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Ortech ODE-9010 | 90 / 81.3 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
Is Panasonic Eco Solutions RG-V80A sized right for your shower or tub room?
Check whether Panasonic Eco Solutions RG-V80A clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
When does Panasonic Eco Solutions RG-V80A fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic Eco Solutions RG-V80A.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 29 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 79.2 CFM net static output
- Target scenario: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Panasonic Eco Solutions RG-V80A?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic Eco Solutions RG-V80A.
Which bathroom layouts should pick a larger blower than Panasonic Eco Solutions RG-V80A?
Do not force Panasonic Eco Solutions RG-V80A into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Panasonic Eco Solutions RG-V80A retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Panasonic Eco Solutions RG-V80A produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Panasonic Eco Solutions RG-V80A disturb adjacent bedrooms during night use?
Acoustic measurement places Panasonic Eco Solutions RG-V80A at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Panasonic Eco Solutions RG-V80A continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Panasonic Eco Solutions RG-V80A draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Panasonic Eco Solutions RG-V80A pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic Eco Solutions RG-V80A's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic Eco Solutions RG-V80A?
Panasonic Eco Solutions RG-V80A features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic Eco Solutions RG-V80A's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic Eco Solutions RG-V80A's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Panasonic Eco Solutions RG-V80A code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic Eco Solutions RG-V80A clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)