Rated for 90 CFM open-air (72.6 CFM at 0.25 in. w.g.), Utilitech 7105-09-L registers #412 of 607 in quietness (1.5 sones) and delivers 3.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 72 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7105-09-L Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 72.6 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 80.7% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Utilitech 7105-09-L vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 90 CFM open-air to 72.6 CFM at 0.25 in. w.g. (80.7% retention, 7.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Utilitech's 22-unit lineup, 7105-09-L (series: 7105-09-L) carries PD #2405421 dating to 2022-11-18. Lighting kit: Yes. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Home Netwerks 7105-09-BN (90.0 CFM) and HomeWerks Worldwide 7105-09-MB (90.0 CFM).
How does Utilitech 7105-09-L acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Utilitech 7105-09-L (1.5 sones).
How do flex elbows choke Utilitech 7105-09-L at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Utilitech 7105-09-L moving full rated CFM.
Does Utilitech 7105-09-L meet residential exhaust fan code specs?
Inspect Utilitech 7105-09-L mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Utilitech (22 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7105-09-L / 7105-09-L | PD ID 2405421 (Qualified 2022-11-18) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (72.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Utilitech 7105-09-L airflow output?
Annual electricity figures and room square-footage ceilings below reflect Utilitech 7105-09-L tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 72 sq ft | 1 CFM/sq ft @ 72.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 64 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 22 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
Which competing models share Utilitech 7105-09-L airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Home Netwerks 7105-09-BN | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7105-09-MB | 90 / 72.6 CFM | 1.5 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Air King FR90 | 90 / 73.2 CFM | 1.5 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-11 | 90 / 82 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Akicon AK1390N1-W/B/S | 90 / 67.4 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
How much airflow margin does Utilitech 7105-09-L give your bath?
Run a quick local room-volume check for Utilitech 7105-09-L by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Utilitech 7105-09-L?
Match Utilitech 7105-09-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 22 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 72 sq ft with 8-ft ceilings (64 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Utilitech 7105-09-L?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Utilitech 7105-09-L.
What does Utilitech 7105-09-L cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Utilitech 7105-09-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Utilitech 7105-09-L pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7105-09-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Utilitech 7105-09-L?
Utilitech 7105-09-L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Utilitech 7105-09-L's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7105-09-L's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Utilitech 7105-09-L ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7105-09-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Utilitech 7105-09-L run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Utilitech 7105-09-L.
What happens to Utilitech 7105-09-L CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Utilitech 7105-09-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Utilitech 7105-09-L sit on acoustic comfort for senior homeowners?
Measuring 1.5 sones, Utilitech 7105-09-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)