Skip to main content
Grant Estimator

Utilitech 7105-09-L Exhaust Fan Specifications

ENERGY STAR PD #2405421 · Bathroom/Utility Room · Qualified 2022-11-18
Verified Specification Summary

Rated for 90 CFM open-air (72.6 CFM at 0.25 in. w.g.), Utilitech 7105-09-L registers #412 of 607 in quietness (1.5 sones) and delivers 3.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 72 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7105-09-L Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 72.6 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
3.6 CFM/W (#1,017/1,145)
Static Retention
80.7% @ 0.25"
Motor Draw
25.0 W (9.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Utilitech 7105-09-L vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 90 CFM open-air to 72.6 CFM at 0.25 in. w.g. (80.7% retention, 7.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Utilitech's 22-unit lineup, 7105-09-L (series: 7105-09-L) carries PD #2405421 dating to 2022-11-18. Lighting kit: Yes. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include Home Netwerks 7105-09-BN (90.0 CFM) and HomeWerks Worldwide 7105-09-MB (90.0 CFM).

How does Utilitech 7105-09-L acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Utilitech 7105-09-L (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke Utilitech 7105-09-L at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Utilitech 7105-09-L moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Utilitech 7105-09-L meet residential exhaust fan code specs?

Inspect Utilitech 7105-09-L mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Utilitech (22 models) ENERGY STAR Certified Partner
Model Number & Series 7105-09-L / 7105-09-L PD ID 2405421 (Qualified 2022-11-18)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (72.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Utilitech 7105-09-L airflow output?

Annual electricity figures and room square-footage ceilings below reflect Utilitech 7105-09-L tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Utilitech 7105-09-L
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 72 sq ft1 CFM/sq ft @ 72.6 CFM
Tall Bath (9-ft Ceiling)Up to 64 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 22 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.1 kWh/yr (~$1.46/yr)25.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2219.0 kWh/yr (~$35.04/yr)25.0 W x 8,760 hrs / 1,000

Which competing models share Utilitech 7105-09-L airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Home Netwerks 7105-09-BN 90 / 72.6 CFM 1.5 sones (Same) 3.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7105-09-MB 90 / 72.6 CFM 1.5 sones (Same) 3.6 CFM/W 4 in. diameter
Air King FR90 90 / 73.2 CFM 1.5 sones (Same) 3.7 CFM/W 4 in. diameter
Tech Drive TD-BF-11 90 / 82 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Akicon AK1390N1-W/B/S 90 / 67.4 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter

How much airflow margin does Utilitech 7105-09-L give your bath?

Run a quick local room-volume check for Utilitech 7105-09-L by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Utilitech 7105-09-L?

Match Utilitech 7105-09-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 22 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 72 sq ft with 8-ft ceilings (64 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Utilitech 7105-09-L?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Utilitech 7105-09-L.

What does Utilitech 7105-09-L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Utilitech 7105-09-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Utilitech 7105-09-L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7105-09-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Utilitech 7105-09-L?

Utilitech 7105-09-L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Utilitech 7105-09-L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7105-09-L's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Utilitech 7105-09-L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7105-09-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Utilitech 7105-09-L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Utilitech 7105-09-L.

What happens to Utilitech 7105-09-L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Utilitech 7105-09-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Utilitech 7105-09-L sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Utilitech 7105-09-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories