Broan-Nutone BE8 Exhaust Fan Specifications

ENERGY STAR PD #3555307 · Bathroom/Utility Room · Qualified 2024-07-12
Verified Specification Summary

Rated for 80 CFM open-air (70.5 CFM at 0.25 in. w.g.), Broan-Nutone BE8 registers #412 of 607 in quietness (1.5 sones) and delivers 4.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 70 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone BE8 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 70.5 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
88.1% @ 0.25"
Motor Draw
19.5 W (7.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone BE8 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.5 CFM out of 80 CFM (88.1% retention, 0.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places BE8 (series: ROOMSIDE) (PD #3555307) among 48 Broan-Nutone entries qualified through 2024-07-12. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 19.5 watts, about 7.1 kWh/yr (~$1.14/yr at $0.16/kWh) for 1 hr/day shower timers or 170.8 kWh/yr (~$27.33/yr) continuously. Closest competing matches include Commercial Electric 7130-18-CE (80.0 CFM) and HomeWerks Worldwide 7130-19-BT (80.0 CFM).

How does Broan-Nutone BE8 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan-Nutone BE8 (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke Broan-Nutone BE8 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan-Nutone BE8 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan-Nutone BE8 meet residential exhaust fan code specs?

Inspect Broan-Nutone BE8 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series BE8 / ROOMSIDE PD ID 3555307 (Qualified 2024-07-12)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (70.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Broan-Nutone BE8 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan-Nutone BE8 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan-Nutone BE8
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 70 sq ft1 CFM/sq ft @ 70.5 CFM
Tall Bath (9-ft Ceiling)Up to 62 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 20 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.1 kWh/yr (~$1.14/yr)19.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2170.8 kWh/yr (~$27.33/yr)19.5 W x 8,760 hrs / 1,000

Which competing models share Broan-Nutone BE8 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric 7130-18-CE 80 / 64 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
HomeWerks Worldwide 7130-19-BT 80 / 69.1 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
PROJECT SOURCE 8781-80-PS 80 / 61.2 CFM 1.5 sones (Same) 3.9 CFM/W 4 in. diameter
Air King AK80 80 / 68.8 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Commercial Electric BPT13-14D 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter

How much airflow margin does Broan-Nutone BE8 give your bath?

Run a quick local room-volume check for Broan-Nutone BE8 by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Broan-Nutone BE8 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan-Nutone BE8 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 20 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 70 sq ft with 8-ft ceilings (62 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Broan-Nutone BE8?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan-Nutone BE8.

What duct and room conditions disqualify Broan-Nutone BE8?

Rule out Broan-Nutone BE8 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Broan-Nutone BE8 capacity?

Because static drag at 0.25 in. w.g. lowers Broan-Nutone BE8 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan-Nutone BE8 compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, Broan-Nutone BE8 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Broan-Nutone BE8 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan-Nutone BE8 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan-Nutone BE8 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone BE8's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone BE8?

Broan-Nutone BE8 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone BE8's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone BE8's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan-Nutone BE8 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone BE8 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.