Skip to main content
Grant Estimator

Broan-Nutone BE8 = BEH with BE8F Exhaust Fan Specifications

ENERGY STAR PD #3629543 · Bathroom/Utility Room · Qualified 2024-07-12
Verified Specification Summary

Certified by EPA ENERGY STAR, Broan-Nutone BE8 = BEH with BE8F delivers 80 CFM free-air (70.5 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 70 sq ft (8-ft height) or 62 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone BE8 = BEH with BE8F Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 70.5 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
88.1% @ 0.25"
Motor Draw
19.5 W (7.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone BE8 = BEH with BE8F vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.5 CFM out of 80 CFM (88.1% retention, 0.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places BE8 = BEH with BE8F (series: ROOMSIDE) (PD #3629543) among 48 Broan-Nutone entries qualified through 2024-07-12. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 19.5 watts, about 7.1 kWh/yr (~$1.14/yr at $0.16/kWh) for 1 hr/day shower timers or 170.8 kWh/yr (~$27.33/yr) continuously. Closest competing matches include Commercial Electric 7130-18-CE (80.0 CFM) and HomeWerks Worldwide 7130-19-BT (80.0 CFM).

How noisy is Broan-Nutone BE8 = BEH with BE8F compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan-Nutone BE8 = BEH with BE8F measures 1.5 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why does rigid 4 in. diameter ducting protect Broan-Nutone BE8 = BEH with BE8F airflow?

Connecting Broan-Nutone BE8 = BEH with BE8F through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Broan-Nutone BE8 = BEH with BE8F performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan-Nutone BE8 = BEH with BE8F lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series BE8 = BEH with BE8F / ROOMSIDE PD ID 3629543 (Qualified 2024-07-12)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (70.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Broan-Nutone BE8 = BEH with BE8F?

Calculated coverage metrics translate Broan-Nutone BE8 = BEH with BE8F airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan-Nutone BE8 = BEH with BE8F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 70 sq ft1 CFM/sq ft @ 70.5 CFM
Tall Bath (9-ft Ceiling)Up to 62 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 20 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.1 kWh/yr (~$1.14/yr)19.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2170.8 kWh/yr (~$27.33/yr)19.5 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Broan-Nutone BE8 = BEH with BE8F?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric 7130-18-CE 80 / 64 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
HomeWerks Worldwide 7130-19-BT 80 / 69.1 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
PROJECT SOURCE 8781-80-PS 80 / 61.2 CFM 1.5 sones (Same) 3.9 CFM/W 4 in. diameter
Air King AK80 80 / 68.8 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Commercial Electric BPT13-14D 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter

Does Broan-Nutone BE8 = BEH with BE8F match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan-Nutone BE8 = BEH with BE8F percentage capacity without sending data.

When does Broan-Nutone BE8 = BEH with BE8F fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone BE8 = BEH with BE8F.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 20 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 70.5 CFM net static output
  • Target scenario: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Broan-Nutone BE8 = BEH with BE8F?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan-Nutone BE8 = BEH with BE8F.

Does running Broan-Nutone BE8 = BEH with BE8F continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone BE8 = BEH with BE8F draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Broan-Nutone BE8 = BEH with BE8F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone BE8 = BEH with BE8F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone BE8 = BEH with BE8F?

Broan-Nutone BE8 = BEH with BE8F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone BE8 = BEH with BE8F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone BE8 = BEH with BE8F's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Broan-Nutone BE8 = BEH with BE8F code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone BE8 = BEH with BE8F clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Broan-Nutone BE8 = BEH with BE8F?

Do not force Broan-Nutone BE8 = BEH with BE8F into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Broan-Nutone BE8 = BEH with BE8F retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone BE8 = BEH with BE8F produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Broan-Nutone BE8 = BEH with BE8F disturb adjacent bedrooms during night use?

Acoustic measurement places Broan-Nutone BE8 = BEH with BE8F at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories