Commercial Electric BPT13-14D Exhaust Fan Specifications

ENERGY STAR PD #3531079 · Bathroom/Utility Room · Qualified 2024-05-24
Verified Specification Summary

Certified by EPA ENERGY STAR, Commercial Electric BPT13-14D delivers 80 CFM free-air (57.7 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 57 sq ft (8-ft height) or 51 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BPT13-14D Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 57.7 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
72.1% @ 0.25"
Motor Draw
18.6 W (6.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Commercial Electric BPT13-14D vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 57.7 CFM at 0.25 in. w.g. (72.1% retention, 15.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Commercial Electric's 15-unit lineup, BPT13-14D (series: BPT13) carries PD #3531079 dating to 2024-05-24. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Air King AK80 (80.0 CFM) and Tech Drive TD-BF-04 (80.0 CFM).

How noisy is Commercial Electric BPT13-14D compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Commercial Electric BPT13-14D measures 1.5 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why does rigid 4 in. diameter ducting protect Commercial Electric BPT13-14D airflow?

Connecting Commercial Electric BPT13-14D through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Commercial Electric BPT13-14D performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Commercial Electric BPT13-14D lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Commercial Electric (15 models) ENERGY STAR Certified Partner
Model Number & Series BPT13-14D / BPT13 PD ID 3531079 (Qualified 2024-05-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (57.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Commercial Electric BPT13-14D?

Calculated coverage metrics translate Commercial Electric BPT13-14D airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Commercial Electric BPT13-14D
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 57 sq ft1 CFM/sq ft @ 57.7 CFM
Tall Bath (9-ft Ceiling)Up to 51 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.8 kWh/yr (~$1.09/yr)18.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2162.9 kWh/yr (~$26.06/yr)18.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Commercial Electric BPT13-14D?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Air King AK80 80 / 68.8 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Tech Drive TD-BF-04 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Tech Drive TD-BF-04-H 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Valu+ BPT13-14DT-2 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
VENTECHLATION BPT13-14DT-1 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter

Does Commercial Electric BPT13-14D match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Commercial Electric BPT13-14D percentage capacity without sending data.

Which bath layouts should avoid specifying Commercial Electric BPT13-14D?

Match Commercial Electric BPT13-14D directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 57.7 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Commercial Electric BPT13-14D?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Commercial Electric BPT13-14D.

What bathroom square footage can Commercial Electric BPT13-14D ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BPT13-14D covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Commercial Electric BPT13-14D run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Commercial Electric BPT13-14D.

What happens to Commercial Electric BPT13-14D CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Commercial Electric BPT13-14D moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Commercial Electric BPT13-14D sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Commercial Electric BPT13-14D produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Commercial Electric BPT13-14D cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Commercial Electric BPT13-14D 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Commercial Electric BPT13-14D pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BPT13-14D's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Commercial Electric BPT13-14D?

Commercial Electric BPT13-14D features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Commercial Electric BPT13-14D's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BPT13-14D's safe coverage footprint from 50 sq ft to 44 sq ft.