The VENTECHLATION BPT13-14DT-1 (BPT) moves 80 CFM at 0.1 in. w.g. (57.7 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.3 CFM/W efficacy, sizing bathrooms up to 57 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION BPT13-14DT-1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 57.7 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 72.1% @ 0.25"
- Motor Draw
- 18.6 W (6.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does VENTECHLATION BPT13-14DT-1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 57.7 CFM at 0.25 in. w.g. (72.1% retention, 15.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: VENTECHLATION registers 12 certified models, with SKU BPT13-14DT-1 (series: BPT) (PD #4429498) certified since 2025-06-06. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Air King AK80 (80.0 CFM) and Commercial Electric BPT13-14D (80.0 CFM).
Where does VENTECHLATION BPT13-14DT-1 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.
How does duct geometry alter VENTECHLATION BPT13-14DT-1 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to VENTECHLATION BPT13-14DT-1?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for VENTECHLATION BPT13-14DT-1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT13-14DT-1 / BPT | PD ID 4429498 (Qualified 2025-06-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (57.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can VENTECHLATION BPT13-14DT-1 ventilate safely?
Sizing outputs below convert VENTECHLATION BPT13-14DT-1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 57 sq ft | 1 CFM/sq ft @ 57.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 51 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.8 kWh/yr (~$1.09/yr) | 18.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 162.9 kWh/yr (~$26.06/yr) | 18.6 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match VENTECHLATION BPT13-14DT-1 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King AK80 | 80 / 68.8 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT13-14D | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT13-14HD | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-04 | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-04-H | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
Will VENTECHLATION BPT13-14DT-1 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether VENTECHLATION BPT13-14DT-1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
What plumbing or duct constraints rule out VENTECHLATION BPT13-14DT-1?
Compare where VENTECHLATION BPT13-14DT-1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 57 sq ft with 8-ft ceilings (51 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern VENTECHLATION BPT13-14DT-1?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting VENTECHLATION BPT13-14DT-1.
How does VENTECHLATION BPT13-14DT-1 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., VENTECHLATION BPT13-14DT-1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is VENTECHLATION BPT13-14DT-1 quiet enough for a primary bedroom bathroom?
At 1.5 sones, VENTECHLATION BPT13-14DT-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is VENTECHLATION BPT13-14DT-1 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can VENTECHLATION BPT13-14DT-1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION BPT13-14DT-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VENTECHLATION BPT13-14DT-1?
VENTECHLATION BPT13-14DT-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VENTECHLATION BPT13-14DT-1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION BPT13-14DT-1's safe coverage footprint from 50 sq ft to 44 sq ft.
Can VENTECHLATION BPT13-14DT-1 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: VENTECHLATION BPT13-14DT-1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap VENTECHLATION BPT13-14DT-1 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, VENTECHLATION BPT13-14DT-1 lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)