Commercial Electric BPT13-14HD Exhaust Fan Specifications

ENERGY STAR PD #3531078 · Bathroom/Utility Room · Qualified 2024-05-24
Verified Specification Summary

Rated for 80 CFM open-air (57.7 CFM at 0.25 in. w.g.), Commercial Electric BPT13-14HD registers #412 of 607 in quietness (1.5 sones) and delivers 4.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 57 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BPT13-14HD Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 57.7 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
72.1% @ 0.25"
Motor Draw
18.6 W (6.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Commercial Electric BPT13-14HD vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 57.7 CFM at 0.25 in. w.g. (72.1% retention, 15.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Commercial Electric registers 15 certified models, with SKU BPT13-14HD (series: BPT13) (PD #3531078) certified since 2024-05-24. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Air King AK80 (80.0 CFM) and Tech Drive TD-BF-04 (80.0 CFM).

How does Commercial Electric BPT13-14HD acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Commercial Electric BPT13-14HD (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke Commercial Electric BPT13-14HD at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Commercial Electric BPT13-14HD moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Commercial Electric BPT13-14HD meet residential exhaust fan code specs?

Inspect Commercial Electric BPT13-14HD mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Commercial Electric (15 models) ENERGY STAR Certified Partner
Model Number & Series BPT13-14HD / BPT13 PD ID 3531078 (Qualified 2024-05-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (57.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Commercial Electric BPT13-14HD airflow output?

Annual electricity figures and room square-footage ceilings below reflect Commercial Electric BPT13-14HD tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Commercial Electric BPT13-14HD
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 57 sq ft1 CFM/sq ft @ 57.7 CFM
Tall Bath (9-ft Ceiling)Up to 51 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.8 kWh/yr (~$1.09/yr)18.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2162.9 kWh/yr (~$26.06/yr)18.6 W x 8,760 hrs / 1,000

Which competing models share Commercial Electric BPT13-14HD airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Air King AK80 80 / 68.8 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Tech Drive TD-BF-04 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Tech Drive TD-BF-04-H 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Valu+ BPT13-14DT-2 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
VENTECHLATION BPT13-14DT-1 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter

How much airflow margin does Commercial Electric BPT13-14HD give your bath?

Run a quick local room-volume check for Commercial Electric BPT13-14HD by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Commercial Electric BPT13-14HD on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Commercial Electric BPT13-14HD carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 57 sq ft with 8-ft ceilings (51 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Commercial Electric BPT13-14HD?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Commercial Electric BPT13-14HD.

What duct and room conditions disqualify Commercial Electric BPT13-14HD?

Rule out Commercial Electric BPT13-14HD when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Commercial Electric BPT13-14HD capacity?

Because static drag at 0.25 in. w.g. lowers Commercial Electric BPT13-14HD from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Commercial Electric BPT13-14HD compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, Commercial Electric BPT13-14HD produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Commercial Electric BPT13-14HD consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Commercial Electric BPT13-14HD draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Commercial Electric BPT13-14HD pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BPT13-14HD's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Commercial Electric BPT13-14HD?

Commercial Electric BPT13-14HD features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Commercial Electric BPT13-14HD's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BPT13-14HD's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Commercial Electric BPT13-14HD score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BPT13-14HD delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.