Rated for 80 CFM open-air (62.9 CFM at 0.25 in. w.g.), Delta 80RLED-ADJ registers #412 of 607 in quietness (1.5 sones) and delivers 7.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 62 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 80RLED-ADJ Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 62.9 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 7.2 CFM/W (#407/1,145)
- Static Retention
- 78.6% @ 0.25"
- Motor Draw
- 11.1 W (4.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta 80RLED-ADJ vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.9 CFM at 0.25 in. w.g. (78.6% retention, 9.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Delta's 121-unit lineup, 80RLED-ADJ (series: BreezIntegrity) carries PD #2343324 dating to 2018-09-28. Lighting kit: Yes. At 7.2 CFM/W (#407 of 1,145, top 36.2% of 1,145 rated models, more efficient than 63.8% of rated models, 2.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.1 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 97.2 kWh/yr (~$15.55/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta 80F-LED (80.0 CFM).
How does Delta 80RLED-ADJ acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Delta 80RLED-ADJ (1.5 sones).
How do flex elbows choke Delta 80RLED-ADJ at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Delta 80RLED-ADJ moving full rated CFM.
Does Delta 80RLED-ADJ meet residential exhaust fan code specs?
Inspect Delta 80RLED-ADJ mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 80RLED-ADJ / BreezIntegrity | PD ID 2343324 (Qualified 2018-09-28) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (62.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Delta 80RLED-ADJ airflow output?
Annual electricity figures and room square-footage ceilings below reflect Delta 80RLED-ADJ tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 62 sq ft | 1 CFM/sq ft @ 62.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 55 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.1 kWh/yr (~$0.66/yr) | 11.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 97.2 kWh/yr (~$15.55/yr) | 11.1 W x 8,760 hrs / 1,000 |
Which competing models share Delta 80RLED-ADJ airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7142-70-L | 70 / 55.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 3 in. diameter |
| Delta 80F-LED | 80 / 61.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-BN | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-MB | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta ITG80RLED-ADJ | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
How much airflow margin does Delta 80RLED-ADJ give your bath?
Run a quick local room-volume check for Delta 80RLED-ADJ by entering square footage and ceiling height to spot under-vented steam risks early.
What plumbing or duct constraints rule out Delta 80RLED-ADJ?
Compare where Delta 80RLED-ADJ excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 62 sq ft with 8-ft ceilings (55 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Delta 80RLED-ADJ?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta 80RLED-ADJ.
Why might a contractor swap Delta 80RLED-ADJ for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta 80RLED-ADJ lacks adequate reserve.
How does Delta 80RLED-ADJ handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta 80RLED-ADJ yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Delta 80RLED-ADJ quiet enough for a primary bedroom bathroom?
At 1.5 sones, Delta 80RLED-ADJ produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Delta 80RLED-ADJ energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta 80RLED-ADJ pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 80RLED-ADJ's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta 80RLED-ADJ?
Delta 80RLED-ADJ features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta 80RLED-ADJ's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 80RLED-ADJ's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Delta 80RLED-ADJ serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta 80RLED-ADJ supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)