Skip to main content
Grant Estimator

Delta 80RLED-ADJ-MB Exhaust Fan Specifications

ENERGY STAR PD #2374796 · Bathroom/Utility Room · Qualified 2021-03-12
Verified Specification Summary

In EPA dataset 8dv7-nngq, Delta 80RLED-ADJ-MB tests at 80 CFM free discharge (62.9 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 7.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 62 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 80RLED-ADJ-MB Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 62.9 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
7.2 CFM/W (#407/1,145)
Static Retention
78.6% @ 0.25"
Motor Draw
11.1 W (4.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta 80RLED-ADJ-MB vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.9 CFM at 0.25 in. w.g. (78.6% retention, 9.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta 80RLED-ADJ-MB (series: BreezIntegrity) under PD #2374796 (121 models registered, 2021-03-12). Lighting kit: Yes. At 7.2 CFM/W (#407 of 1,145, top 36.2% of 1,145 rated models, more efficient than 63.8% of rated models, 2.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.1 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 97.2 kWh/yr (~$15.55/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta 80F-LED (80.0 CFM).

Does Delta 80RLED-ADJ-MB fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta 80RLED-ADJ-MB at 1.5 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why avoid unvented attic termination with Delta 80RLED-ADJ-MB?

Under ASHRAE 62.2 best practice, Delta 80RLED-ADJ-MB needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Delta 80RLED-ADJ-MB?

Before cutting ceiling drywall or sizing attic transitions for Delta 80RLED-ADJ-MB, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series 80RLED-ADJ-MB / BreezIntegrity PD ID 2374796 (Qualified 2021-03-12)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (62.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Delta 80RLED-ADJ-MB?

Bathroom ventilation sizing below maps Delta 80RLED-ADJ-MB motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Delta 80RLED-ADJ-MB
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 62 sq ft1 CFM/sq ft @ 62.9 CFM
Tall Bath (9-ft Ceiling)Up to 55 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.1 kWh/yr (~$0.66/yr)11.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.297.2 kWh/yr (~$15.55/yr)11.1 W x 8,760 hrs / 1,000

What peer models sit nearest Delta 80RLED-ADJ-MB in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta 80RLED-ADJ-MB.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7142-70-L 70 / 55.5 CFM 1.5 sones (Same) 7.2 CFM/W 3 in. diameter
Delta 80F-LED 80 / 61.5 CFM 1.5 sones (Same) 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ 80 / 62.9 CFM 1.5 sones (Same) 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ-BN 80 / 62.9 CFM 1.5 sones (Same) 7.2 CFM/W 4 in. diameter
Delta ITG80RLED-ADJ 80 / 62.9 CFM 1.5 sones (Same) 7.2 CFM/W 4 in. diameter

What percentage of room demand does Delta 80RLED-ADJ-MB cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta 80RLED-ADJ-MB tested delivery.

What plumbing or duct constraints rule out Delta 80RLED-ADJ-MB?

Compare where Delta 80RLED-ADJ-MB excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 62.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 1.5 sones up to 62 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Delta 80RLED-ADJ-MB?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta 80RLED-ADJ-MB.

How does Delta 80RLED-ADJ-MB handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta 80RLED-ADJ-MB yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Delta 80RLED-ADJ-MB quiet enough for a primary bedroom bathroom?

At 1.5 sones, Delta 80RLED-ADJ-MB produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Delta 80RLED-ADJ-MB energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta 80RLED-ADJ-MB pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 80RLED-ADJ-MB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta 80RLED-ADJ-MB?

Delta 80RLED-ADJ-MB features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta 80RLED-ADJ-MB's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 80RLED-ADJ-MB's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta 80RLED-ADJ-MB serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta 80RLED-ADJ-MB supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Delta 80RLED-ADJ-MB for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta 80RLED-ADJ-MB lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories