Skip to main content
Grant Estimator

Delta 80F-LED Exhaust Fan Specifications

ENERGY STAR PD #2343317 · Bathroom/Utility Room · Qualified 2018-03-30
Verified Specification Summary

Certified by EPA ENERGY STAR, Delta 80F-LED delivers 80 CFM free-air (61.5 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 7.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 61 sq ft (8-ft height) or 54 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 80F-LED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 61.5 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
7.2 CFM/W (#407/1,145)
Static Retention
76.9% @ 0.25"
Motor Draw
11.1 W (4.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta 80F-LED vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.5 CFM at 0.25 in. w.g. (76.9% retention, 10.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Delta's 121-unit lineup, 80F-LED (series: BreezIntegrity) carries PD #2343317 dating to 2018-03-30. Lighting kit: Yes. At 7.2 CFM/W (#407 of 1,145, top 36.2% of 1,145 rated models, more efficient than 63.8% of rated models, 2.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.1 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 97.2 kWh/yr (~$15.55/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta 80RLED-ADJ (80.0 CFM).

How noisy is Delta 80F-LED compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Delta 80F-LED measures 1.5 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why does rigid 4 in. diameter ducting protect Delta 80F-LED airflow?

Connecting Delta 80F-LED through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Delta 80F-LED performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta 80F-LED lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series 80F-LED / BreezIntegrity PD ID 2343317 (Qualified 2018-03-30)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (61.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Delta 80F-LED?

Calculated coverage metrics translate Delta 80F-LED airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta 80F-LED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 61 sq ft1 CFM/sq ft @ 61.5 CFM
Tall Bath (9-ft Ceiling)Up to 54 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.1 kWh/yr (~$0.66/yr)11.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.297.2 kWh/yr (~$15.55/yr)11.1 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Delta 80F-LED?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7142-70-L 70 / 55.5 CFM 1.5 sones (Same) 7.2 CFM/W 3 in. diameter
Delta 80RLED-ADJ 80 / 62.9 CFM 1.5 sones (Same) 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ-BN 80 / 62.9 CFM 1.5 sones (Same) 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ-MB 80 / 62.9 CFM 1.5 sones (Same) 7.2 CFM/W 4 in. diameter
Delta ITG80RLED-ADJ 80 / 62.9 CFM 1.5 sones (Same) 7.2 CFM/W 4 in. diameter

Does Delta 80F-LED match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta 80F-LED percentage capacity without sending data.

What plumbing or duct constraints rule out Delta 80F-LED?

Compare where Delta 80F-LED excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 61.5 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Delta 80F-LED?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta 80F-LED.

Is Delta 80F-LED energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta 80F-LED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 80F-LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta 80F-LED?

Delta 80F-LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta 80F-LED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 80F-LED's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta 80F-LED serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta 80F-LED supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Delta 80F-LED for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta 80F-LED lacks adequate reserve.

How does Delta 80F-LED handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta 80F-LED yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Delta 80F-LED quiet enough for a primary bedroom bathroom?

At 1.5 sones, Delta 80F-LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories