Certified by EPA ENERGY STAR, Utilitech 7142-70-L delivers 70 CFM free-air (55.5 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 7.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 55 sq ft (8-ft height) or 49 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7142-70-L Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 55.5 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 7.2 CFM/W (#407/1,145)
- Static Retention
- 79.3% @ 0.25"
- Motor Draw
- 9.7 W (3.5 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Utilitech 7142-70-L vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 70 CFM open-air to 55.5 CFM at 0.25 in. w.g. (79.3% retention, 8.4 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3629311 verifies 7142-70-L (series: Utilitech) under Utilitech (22 listed models, qualified 2024-08-30). Lighting kit: No. At 7.2 CFM/W (#407 of 1,145, top 36.2% of 1,145 rated models, more efficient than 63.8% of rated models, 2.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.7 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 85.0 kWh/yr (~$13.60/yr) continuously. Closest competing matches include Delta 80F-LED (80.0 CFM) and Delta 80RLED-ADJ (80.0 CFM).
How noisy is Utilitech 7142-70-L compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Utilitech 7142-70-L measures 1.5 sones across the 1,145-model registry.
Why does rigid 3 in. diameter ducting protect Utilitech 7142-70-L airflow?
Connecting Utilitech 7142-70-L through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Utilitech 7142-70-L performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Utilitech 7142-70-L lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Utilitech (22 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7142-70-L / Utilitech | PD ID 3629311 (Qualified 2024-08-30) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (55.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Utilitech 7142-70-L?
Calculated coverage metrics translate Utilitech 7142-70-L airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 55 sq ft | 1 CFM/sq ft @ 55.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 49 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.5 kWh/yr (~$0.56/yr) | 9.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 85.0 kWh/yr (~$13.60/yr) | 9.7 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Utilitech 7142-70-L?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta 80F-LED | 80 / 61.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-BN | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-MB | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta ITG80RLED-ADJ | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
Does Utilitech 7142-70-L match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Utilitech 7142-70-L percentage capacity without sending data.
Which bath layouts should avoid specifying Utilitech 7142-70-L?
Match Utilitech 7142-70-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 55.5 CFM net static output
- Optimal use: Collar pairs with 3 in. diameter duct straight outdoors
Which homeowner questions come up most for Utilitech 7142-70-L?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Utilitech 7142-70-L.
Where does Utilitech 7142-70-L run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Utilitech 7142-70-L.
What happens to Utilitech 7142-70-L CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Utilitech 7142-70-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3 in. diameter collar.
Where does Utilitech 7142-70-L sit on acoustic comfort for senior homeowners?
Measuring 1.5 sones, Utilitech 7142-70-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Utilitech 7142-70-L cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Utilitech 7142-70-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Utilitech 7142-70-L pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7142-70-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Utilitech 7142-70-L?
Utilitech 7142-70-L features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Utilitech 7142-70-L's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7142-70-L's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Utilitech 7142-70-L ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7142-70-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)