Rated for 70 CFM open-air (60.3 CFM at 0.25 in. w.g.), Tech Drive FA-BF-02-L registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 60 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive FA-BF-02-L Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 60.3 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 86.1% @ 0.25"
- Motor Draw
- 17.5 W (6.4 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Tech Drive FA-BF-02-L vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.3 CFM out of 70 CFM (86.1% retention, 1.6 pts lower retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places FA-BF-02-L (series: FA) (PD #3814681) among 27 Tech Drive entries qualified through 2024-11-22. Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.5 watts, about 6.4 kWh/yr (~$1.02/yr at $0.16/kWh) for 1 hr/day shower timers or 153.3 kWh/yr (~$24.53/yr) continuously. Closest competing matches include Broan 744 (70.0 CFM) and Broan 744FL (70.0 CFM).
How does Tech Drive FA-BF-02-L acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Tech Drive FA-BF-02-L (1.5 sones).
How do flex elbows choke Tech Drive FA-BF-02-L at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Tech Drive FA-BF-02-L moving full rated CFM.
Does Tech Drive FA-BF-02-L meet residential exhaust fan code specs?
Inspect Tech Drive FA-BF-02-L mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FA-BF-02-L / FA | PD ID 3814681 (Qualified 2024-11-22) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Tech Drive FA-BF-02-L airflow output?
Annual electricity figures and room square-footage ceilings below reflect Tech Drive FA-BF-02-L tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.4 kWh/yr (~$1.02/yr) | 17.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 153.3 kWh/yr (~$24.53/yr) | 17.5 W x 8,760 hrs / 1,000 |
Which competing models share Tech Drive FA-BF-02-L airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 744 | 70 / 58.3 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan 744FL | 70 / 58.3 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan 744LED | 70 / 58.3 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Commercial Electric 7130-18-CE | 80 / 64 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan-Nutone BE8 | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
How much airflow margin does Tech Drive FA-BF-02-L give your bath?
Run a quick local room-volume check for Tech Drive FA-BF-02-L by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Tech Drive FA-BF-02-L?
Match Tech Drive FA-BF-02-L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 3 in. diameter
What should homeowners verify first about Tech Drive FA-BF-02-L?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Tech Drive FA-BF-02-L.
What happens to Tech Drive FA-BF-02-L CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Tech Drive FA-BF-02-L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3 in. diameter collar.
Where does Tech Drive FA-BF-02-L sit on acoustic comfort for senior homeowners?
Measuring 1.5 sones, Tech Drive FA-BF-02-L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Tech Drive FA-BF-02-L cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Tech Drive FA-BF-02-L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Tech Drive FA-BF-02-L pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive FA-BF-02-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive FA-BF-02-L?
Tech Drive FA-BF-02-L features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive FA-BF-02-L's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive FA-BF-02-L's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Tech Drive FA-BF-02-L ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Tech Drive FA-BF-02-L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Tech Drive FA-BF-02-L run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Tech Drive FA-BF-02-L.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)