Rated for 70 CFM open-air (58.3 CFM at 0.25 in. w.g.), Broan 744 registers #412 of 607 in quietness (1.5 sones) and delivers 4.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 58 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan 744 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 58.3 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 83.3% @ 0.25"
- Motor Draw
- 17.5 W (6.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan 744 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 70 CFM open-air to 58.3 CFM at 0.25 in. w.g. (83.3% retention, 4.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3360876 verifies 744 (series: RECESSED FAN/LIGHT) under Broan (207 listed models, qualified 2023-12-15). Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.5 watts, about 6.4 kWh/yr (~$1.02/yr at $0.16/kWh) for 1 hr/day shower timers or 153.3 kWh/yr (~$24.53/yr) continuously. Closest competing matches include Tech Drive FA-BF-02-L (70.0 CFM) and Commercial Electric 7130-18-CE (80.0 CFM).
How does Broan 744 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan 744 (1.5 sones).
How do flex elbows choke Broan 744 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan 744 moving full rated CFM.
Does Broan 744 meet residential exhaust fan code specs?
Inspect Broan 744 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 744 / RECESSED FAN/LIGHT | PD ID 3360876 (Qualified 2023-12-15) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (58.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Broan 744 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan 744 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 58 sq ft | 1 CFM/sq ft @ 58.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 51 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.4 kWh/yr (~$1.02/yr) | 17.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 153.3 kWh/yr (~$24.53/yr) | 17.5 W x 8,760 hrs / 1,000 |
Which competing models share Broan 744 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive FA-BF-02-L | 70 / 60.3 CFM | 1.5 sones (Same) | 4.0 CFM/W | 3 in. diameter |
| Commercial Electric 7130-18-CE | 80 / 64 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan-Nutone BE8 | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Broan-Nutone BE8 = BEH with BE8F | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Broan-Nutone BEL8 | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
How much airflow margin does Broan 744 give your bath?
Run a quick local room-volume check for Broan 744 by entering square footage and ceiling height to spot under-vented steam risks early.
What plumbing or duct constraints rule out Broan 744?
Compare where Broan 744 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 58 sq ft with 8-ft ceilings (51 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Broan 744?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan 744.
How does Broan 744 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan 744 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Broan 744 quiet enough for a primary bedroom bathroom?
At 1.5 sones, Broan 744 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Broan 744 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Broan 744 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan 744's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan 744?
Broan 744 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan 744's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan 744's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Broan 744 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Broan 744 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Broan 744 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan 744 lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)