Tested under HVI protocols, the Delta REC80LED exhaust unit achieves 80 CFM at 0.1 in. w.g. (72.5 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 6.1 CFM/W efficacy, covering standard baths up to 72 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta REC80LED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 72.5 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 6.1 CFM/W (#448/1,145)
- Static Retention
- 90.6% @ 0.25"
- Motor Draw
- 13.1 W (4.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta REC80LED vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 72.5 CFM out of 80 CFM (90.6% retention, 2.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Delta registers 121 certified models, with SKU REC80LED (series: BreezRecessed) (PD #2330677) certified since 2018-11-30. Lighting kit: Yes. At 6.1 CFM/W (#448 of 1,145, top 40.0% of 1,145 rated models, more efficient than 60.0% of rated models, 1.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.1 watts, about 4.8 kWh/yr (~$0.77/yr at $0.16/kWh) for 1 hr/day shower timers or 114.8 kWh/yr (~$18.37/yr) continuously. Closest competing matches include Tech Drive FA-BF-03-L(BL) (80.0 CFM) and Tech Drive FA-BF-03-L(BN) (80.0 CFM).
Where do Delta REC80LED sones rank across EPA ENERGY STAR fans?
Comparing Delta REC80LED (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Delta REC80LED CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta REC80LED, preventing premature peeling paint and mold growth.
How does Delta REC80LED measure up on airflow and noise ratings?
Each row below breaks down Delta REC80LED certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | REC80LED / BreezRecessed | PD ID 2330677 (Qualified 2018-11-30) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (72.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Delta REC80LED CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 72 sq ft | 1 CFM/sq ft @ 72.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 64 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 22 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.8 kWh/yr (~$0.77/yr) | 13.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 114.8 kWh/yr (~$18.37/yr) | 13.1 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Delta REC80LED?
Compare Delta REC80LED side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive FA-BF-03-L(BL) | 80 / 62.4 CFM | 1.5 sones (Same) | 4.6 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-03-L(BN) | 80 / 62.4 CFM | 1.5 sones (Same) | 4.6 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-03-L(WH) | 80 / 62.4 CFM | 1.5 sones (Same) | 4.6 CFM/W | 4 in. diameter |
| Utilitech 7142-70-L | 70 / 55.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 3 in. diameter |
| Air King AK80 | 80 / 68.8 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
Can you size Delta REC80LED for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta REC80LED verified capacity.
Which bath layouts should avoid specifying Delta REC80LED?
Match Delta REC80LED directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 72.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 1.5 sones up to 72 sq ft
- Optimal use: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Delta REC80LED?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta REC80LED.
Where does Delta REC80LED run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta REC80LED.
What happens to Delta REC80LED CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Delta REC80LED moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does Delta REC80LED sit on acoustic comfort for senior homeowners?
Measuring 1.5 sones, Delta REC80LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Delta REC80LED cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Delta REC80LED 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Delta REC80LED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta REC80LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta REC80LED?
Delta REC80LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta REC80LED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta REC80LED's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Delta REC80LED ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta REC80LED covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)