The Tech Drive FA-BF-03-L(BL) (FA) moves 80 CFM at 0.1 in. w.g. (62.4 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.6 CFM/W efficacy, sizing bathrooms up to 62 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive FA-BF-03-L(BL) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 62.4 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 78.0% @ 0.25"
- Motor Draw
- 17.4 W (6.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Tech Drive FA-BF-03-L(BL) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.4 CFM at 0.25 in. w.g. (78.0% retention, 9.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Tech Drive FA-BF-03-L(BL) (series: FA) under PD #4429509 (27 models registered, 2025-06-06). Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.4 watts, about 6.4 kWh/yr (~$1.02/yr at $0.16/kWh) for 1 hr/day shower timers or 152.4 kWh/yr (~$24.38/yr) continuously. Closest competing matches include Air King AK80 (80.0 CFM) and Commercial Electric BPT13-14D (80.0 CFM).
Where does Tech Drive FA-BF-03-L(BL) sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.
How does duct geometry alter Tech Drive FA-BF-03-L(BL) static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Tech Drive FA-BF-03-L(BL)?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Tech Drive FA-BF-03-L(BL) alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FA-BF-03-L(BL) / FA | PD ID 4429509 (Qualified 2025-06-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (62.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Tech Drive FA-BF-03-L(BL) ventilate safely?
Sizing outputs below convert Tech Drive FA-BF-03-L(BL) tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 62 sq ft | 1 CFM/sq ft @ 62.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 55 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.4 kWh/yr (~$1.02/yr) | 17.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 152.4 kWh/yr (~$24.38/yr) | 17.4 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Tech Drive FA-BF-03-L(BL) closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King AK80 | 80 / 68.8 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT13-14D | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT13-14HD | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Valu+ BPT13-14DT-2 | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| VENTECHLATION BPT13-14DT-1 | 80 / 57.7 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
Will Tech Drive FA-BF-03-L(BL) clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Tech Drive FA-BF-03-L(BL) satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Tech Drive FA-BF-03-L(BL) in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tech Drive FA-BF-03-L(BL) for residential use.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 62 sq ft with 8-ft ceilings (55 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Tech Drive FA-BF-03-L(BL)?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Tech Drive FA-BF-03-L(BL).
Why check Tech Drive FA-BF-03-L(BL) CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tech Drive FA-BF-03-L(BL) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Tech Drive FA-BF-03-L(BL) sound output compare to noisy contractor-grade fans?
Rated at 1.5 sones, Tech Drive FA-BF-03-L(BL) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Tech Drive FA-BF-03-L(BL)?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Tech Drive FA-BF-03-L(BL) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive FA-BF-03-L(BL)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive FA-BF-03-L(BL)?
Tech Drive FA-BF-03-L(BL) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive FA-BF-03-L(BL)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive FA-BF-03-L(BL)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Tech Drive FA-BF-03-L(BL) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tech Drive FA-BF-03-L(BL) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Tech Drive FA-BF-03-L(BL) undersized or poorly matched for a bath renovation?
Skip Tech Drive FA-BF-03-L(BL) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)