Skip to main content
Grant Estimator

S&P PCV80 Exhaust Fan Specifications

ENERGY STAR PD #2271817 · Bathroom/Utility Room · Qualified 2016-07-01
Verified Specification Summary

The S&P PCV80 (PCV) moves 80 CFM at 0.1 in. w.g. (60.8 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 3.4 CFM/W efficacy, sizing bathrooms up to 60 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCV80 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 60.8 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
3.4 CFM/W (#1,060/1,145)
Static Retention
76.0% @ 0.25"
Motor Draw
23.5 W (8.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PCV80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60.8 CFM at 0.25 in. w.g. (76.0% retention, 11.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places PCV80 (series: PCV) (PD #2271817) among 29 S&P entries qualified through 2016-07-01. Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.5 watts, about 8.6 kWh/yr (~$1.38/yr at $0.16/kWh) for 1 hr/day shower timers or 205.9 kWh/yr (~$32.94/yr) continuously. Closest competing matches include HomeWerks Worldwide 7140-80-G3 (80.0 CFM) and HomeWerks Worldwide 7140-80 (80.0 CFM).

Where does S&P PCV80 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How does duct geometry alter S&P PCV80 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to S&P PCV80?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for S&P PCV80 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PCV80 / PCV PD ID 2271817 (Qualified 2016-07-01)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (60.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can S&P PCV80 ventilate safely?

Sizing outputs below convert S&P PCV80 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for S&P PCV80
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 60 sq ft1 CFM/sq ft @ 60.8 CFM
Tall Bath (9-ft Ceiling)Up to 54 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.6 kWh/yr (~$1.38/yr)23.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2205.9 kWh/yr (~$32.94/yr)23.5 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match S&P PCV80 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7140-80-G3 80 / 58.8 CFM 1.5 sones (Same) 3.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7140-80 80 / 57.2 CFM 1.5 sones (Same) 3.5 CFM/W 4 in. diameter
Wintek BPT13B-80-L4 80 / 57.2 CFM 1.5 sones (Same) 3.5 CFM/W 4 in. diameter
PROJECT SOURCE 8781-80-PS 80 / 61.2 CFM 1.5 sones (Same) 3.9 CFM/W 4 in. diameter
Commercial Electric 7130-18-CE 80 / 64 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter

Will S&P PCV80 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether S&P PCV80 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Who should not install S&P PCV80 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting S&P PCV80 for residential use.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 60 sq ft with 8-ft ceilings (54 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern S&P PCV80?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting S&P PCV80.

Why check S&P PCV80 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, S&P PCV80 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does S&P PCV80 sound output compare to noisy contractor-grade fans?

Rated at 1.5 sones, S&P PCV80 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define S&P PCV80?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can S&P PCV80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCV80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PCV80?

S&P PCV80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PCV80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCV80's safe coverage footprint from 50 sq ft to 44 sq ft.

Does S&P PCV80 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), S&P PCV80 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is S&P PCV80 undersized or poorly matched for a bath renovation?

Skip S&P PCV80 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories