Rated for 80 CFM open-air (58.8 CFM at 0.25 in. w.g.), HomeWerks Worldwide 7140-80-G3 registers #412 of 607 in quietness (1.5 sones) and delivers 3.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 58 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7140-80-G3 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 58.8 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 3.4 CFM/W (#1,060/1,145)
- Static Retention
- 73.5% @ 0.25"
- Motor Draw
- 23.5 W (8.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does HomeWerks Worldwide 7140-80-G3 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 58.8 CFM at 0.25 in. w.g. (73.5% retention, 14.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2386422 verifies 7140-80-G3 (series: 7140-80-G3) under HomeWerks Worldwide (31 listed models, qualified 2021-10-15). Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 23.5 watts, about 8.6 kWh/yr (~$1.38/yr at $0.16/kWh) for 1 hr/day shower timers or 205.9 kWh/yr (~$32.94/yr) continuously. Closest competing matches include S&P PCV80 (80.0 CFM) and Wintek BPT13B-80-L4 (80.0 CFM).
How does HomeWerks Worldwide 7140-80-G3 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against HomeWerks Worldwide 7140-80-G3 (1.5 sones).
How do flex elbows choke HomeWerks Worldwide 7140-80-G3 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps HomeWerks Worldwide 7140-80-G3 moving full rated CFM.
Does HomeWerks Worldwide 7140-80-G3 meet residential exhaust fan code specs?
Inspect HomeWerks Worldwide 7140-80-G3 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7140-80-G3 / 7140-80-G3 | PD ID 2386422 (Qualified 2021-10-15) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (58.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match HomeWerks Worldwide 7140-80-G3 airflow output?
Annual electricity figures and room square-footage ceilings below reflect HomeWerks Worldwide 7140-80-G3 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 58 sq ft | 1 CFM/sq ft @ 58.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.6 kWh/yr (~$1.38/yr) | 23.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 205.9 kWh/yr (~$32.94/yr) | 23.5 W x 8,760 hrs / 1,000 |
Which competing models share HomeWerks Worldwide 7140-80-G3 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| S&P PCV80 | 80 / 60.8 CFM | 1.5 sones (Same) | 3.4 CFM/W | 4 in. diameter |
| Wintek BPT13B-80-L4 | 80 / 57.2 CFM | 1.5 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| PROJECT SOURCE 8781-80-PS | 80 / 61.2 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Commercial Electric 7130-18-CE | 80 / 64 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan-Nutone BE8 | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
How much airflow margin does HomeWerks Worldwide 7140-80-G3 give your bath?
Run a quick local room-volume check for HomeWerks Worldwide 7140-80-G3 by entering square footage and ceiling height to spot under-vented steam risks early.
Where should contractors skip HomeWerks Worldwide 7140-80-G3 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for HomeWerks Worldwide 7140-80-G3 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 58 sq ft with 8-ft ceilings (52 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about HomeWerks Worldwide 7140-80-G3?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to HomeWerks Worldwide 7140-80-G3.
How much power does HomeWerks Worldwide 7140-80-G3 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, HomeWerks Worldwide 7140-80-G3 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can HomeWerks Worldwide 7140-80-G3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7140-80-G3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7140-80-G3?
HomeWerks Worldwide 7140-80-G3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7140-80-G3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7140-80-G3's safe coverage footprint from 50 sq ft to 44 sq ft.
How does HomeWerks Worldwide 7140-80-G3 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7140-80-G3 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify HomeWerks Worldwide 7140-80-G3?
Rule out HomeWerks Worldwide 7140-80-G3 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke HomeWerks Worldwide 7140-80-G3 capacity?
Because static drag at 0.25 in. w.g. lowers HomeWerks Worldwide 7140-80-G3 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is HomeWerks Worldwide 7140-80-G3 compared with a standard 3.0 sone builder fan?
Tested at 1.5 sones, HomeWerks Worldwide 7140-80-G3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)