Rated for 80 CFM open-air (61.2 CFM at 0.25 in. w.g.), PROJECT SOURCE 8781-80-PS registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 61 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside PROJECT SOURCE 8781-80-PS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 61.2 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 76.5% @ 0.25"
- Motor Draw
- 20.5 W (7.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does PROJECT SOURCE 8781-80-PS vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.2 CFM at 0.25 in. w.g. (76.5% retention, 11.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places 8781-80-PS (series: 8781-80-PS) (PD #4613834) among 5 PROJECT SOURCE entries qualified through 2026-05-06. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Commercial Electric 7130-18-CE (80.0 CFM) and Broan-Nutone BE8 (80.0 CFM).
How does PROJECT SOURCE 8781-80-PS acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against PROJECT SOURCE 8781-80-PS (1.5 sones).
How do flex elbows choke PROJECT SOURCE 8781-80-PS at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps PROJECT SOURCE 8781-80-PS moving full rated CFM.
Does PROJECT SOURCE 8781-80-PS meet residential exhaust fan code specs?
Inspect PROJECT SOURCE 8781-80-PS mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | PROJECT SOURCE (5 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 8781-80-PS / 8781-80-PS | PD ID 4613834 (Qualified 2026-05-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (61.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match PROJECT SOURCE 8781-80-PS airflow output?
Annual electricity figures and room square-footage ceilings below reflect PROJECT SOURCE 8781-80-PS tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 61 sq ft | 1 CFM/sq ft @ 61.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 54 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |
Which competing models share PROJECT SOURCE 8781-80-PS airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Commercial Electric 7130-18-CE | 80 / 64 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan-Nutone BE8 | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Broan-Nutone BE8 = BEH with BE8F | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Broan-Nutone BEL8 | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Broan-Nutone BELS8 | 80 / 70.5 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
How much airflow margin does PROJECT SOURCE 8781-80-PS give your bath?
Run a quick local room-volume check for PROJECT SOURCE 8781-80-PS by entering square footage and ceiling height to spot under-vented steam risks early.
When does PROJECT SOURCE 8781-80-PS fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering PROJECT SOURCE 8781-80-PS.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 61 sq ft with 8-ft ceilings (54 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about PROJECT SOURCE 8781-80-PS?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to PROJECT SOURCE 8781-80-PS.
How much airflow does PROJECT SOURCE 8781-80-PS retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, PROJECT SOURCE 8781-80-PS produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will PROJECT SOURCE 8781-80-PS disturb adjacent bedrooms during night use?
Acoustic measurement places PROJECT SOURCE 8781-80-PS at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running PROJECT SOURCE 8781-80-PS continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of PROJECT SOURCE 8781-80-PS draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can PROJECT SOURCE 8781-80-PS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from PROJECT SOURCE 8781-80-PS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing PROJECT SOURCE 8781-80-PS?
PROJECT SOURCE 8781-80-PS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change PROJECT SOURCE 8781-80-PS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing PROJECT SOURCE 8781-80-PS's safe coverage footprint from 50 sq ft to 44 sq ft.
Is PROJECT SOURCE 8781-80-PS code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), PROJECT SOURCE 8781-80-PS clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than PROJECT SOURCE 8781-80-PS?
Do not force PROJECT SOURCE 8781-80-PS into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)