PROJECT SOURCE 8781-80-PS Exhaust Fan Specifications

ENERGY STAR PD #4613834 · Bathroom/Utility Room · Qualified 2026-05-06
Verified Specification Summary

Rated for 80 CFM open-air (61.2 CFM at 0.25 in. w.g.), PROJECT SOURCE 8781-80-PS registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 61 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside PROJECT SOURCE 8781-80-PS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 61.2 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
76.5% @ 0.25"
Motor Draw
20.5 W (7.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does PROJECT SOURCE 8781-80-PS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.2 CFM at 0.25 in. w.g. (76.5% retention, 11.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 8781-80-PS (series: 8781-80-PS) (PD #4613834) among 5 PROJECT SOURCE entries qualified through 2026-05-06. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Commercial Electric 7130-18-CE (80.0 CFM) and Broan-Nutone BE8 (80.0 CFM).

How does PROJECT SOURCE 8781-80-PS acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against PROJECT SOURCE 8781-80-PS (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke PROJECT SOURCE 8781-80-PS at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps PROJECT SOURCE 8781-80-PS moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does PROJECT SOURCE 8781-80-PS meet residential exhaust fan code specs?

Inspect PROJECT SOURCE 8781-80-PS mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share PROJECT SOURCE (5 models) ENERGY STAR Certified Partner
Model Number & Series 8781-80-PS / 8781-80-PS PD ID 4613834 (Qualified 2026-05-06)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (61.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match PROJECT SOURCE 8781-80-PS airflow output?

Annual electricity figures and room square-footage ceilings below reflect PROJECT SOURCE 8781-80-PS tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for PROJECT SOURCE 8781-80-PS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 61 sq ft1 CFM/sq ft @ 61.2 CFM
Tall Bath (9-ft Ceiling)Up to 54 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2179.6 kWh/yr (~$28.74/yr)20.5 W x 8,760 hrs / 1,000

Which competing models share PROJECT SOURCE 8781-80-PS airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric 7130-18-CE 80 / 64 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Broan-Nutone BE8 80 / 70.5 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter
Broan-Nutone BE8 = BEH with BE8F 80 / 70.5 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter
Broan-Nutone BEL8 80 / 70.5 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter
Broan-Nutone BELS8 80 / 70.5 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter

How much airflow margin does PROJECT SOURCE 8781-80-PS give your bath?

Run a quick local room-volume check for PROJECT SOURCE 8781-80-PS by entering square footage and ceiling height to spot under-vented steam risks early.

When does PROJECT SOURCE 8781-80-PS fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering PROJECT SOURCE 8781-80-PS.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 61 sq ft with 8-ft ceilings (54 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about PROJECT SOURCE 8781-80-PS?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to PROJECT SOURCE 8781-80-PS.

How much airflow does PROJECT SOURCE 8781-80-PS retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, PROJECT SOURCE 8781-80-PS produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will PROJECT SOURCE 8781-80-PS disturb adjacent bedrooms during night use?

Acoustic measurement places PROJECT SOURCE 8781-80-PS at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running PROJECT SOURCE 8781-80-PS continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of PROJECT SOURCE 8781-80-PS draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can PROJECT SOURCE 8781-80-PS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from PROJECT SOURCE 8781-80-PS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing PROJECT SOURCE 8781-80-PS?

PROJECT SOURCE 8781-80-PS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change PROJECT SOURCE 8781-80-PS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing PROJECT SOURCE 8781-80-PS's safe coverage footprint from 50 sq ft to 44 sq ft.

Is PROJECT SOURCE 8781-80-PS code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), PROJECT SOURCE 8781-80-PS clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than PROJECT SOURCE 8781-80-PS?

Do not force PROJECT SOURCE 8781-80-PS into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.