Tech Drive FA-BF-03-L(WH) Exhaust Fan Specifications

ENERGY STAR PD #4429513 · Bathroom/Utility Room · Qualified 2025-06-06
Verified Specification Summary

Rated for 80 CFM open-air (62.4 CFM at 0.25 in. w.g.), Tech Drive FA-BF-03-L(WH) registers #412 of 607 in quietness (1.5 sones) and delivers 4.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 62 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive FA-BF-03-L(WH) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 62.4 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.6 CFM/W (#578/1,145)
Static Retention
78.0% @ 0.25"
Motor Draw
17.4 W (6.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Tech Drive FA-BF-03-L(WH) vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.4 CFM at 0.25 in. w.g. (78.0% retention, 9.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Tech Drive's 27-unit lineup, FA-BF-03-L(WH) (series: FA) carries PD #4429513 dating to 2025-06-06. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.4 watts, about 6.4 kWh/yr (~$1.02/yr at $0.16/kWh) for 1 hr/day shower timers or 152.4 kWh/yr (~$24.38/yr) continuously. Closest competing matches include Air King AK80 (80.0 CFM) and Commercial Electric BPT13-14D (80.0 CFM).

How does Tech Drive FA-BF-03-L(WH) acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Tech Drive FA-BF-03-L(WH) (1.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How do flex elbows choke Tech Drive FA-BF-03-L(WH) at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Tech Drive FA-BF-03-L(WH) moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Tech Drive FA-BF-03-L(WH) meet residential exhaust fan code specs?

Inspect Tech Drive FA-BF-03-L(WH) mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Tech Drive (27 models) ENERGY STAR Certified Partner
Model Number & Series FA-BF-03-L(WH) / FA PD ID 4429513 (Qualified 2025-06-06)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (62.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Tech Drive FA-BF-03-L(WH) airflow output?

Annual electricity figures and room square-footage ceilings below reflect Tech Drive FA-BF-03-L(WH) tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Tech Drive FA-BF-03-L(WH)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 62 sq ft1 CFM/sq ft @ 62.4 CFM
Tall Bath (9-ft Ceiling)Up to 55 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.4 kWh/yr (~$1.02/yr)17.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2152.4 kWh/yr (~$24.38/yr)17.4 W x 8,760 hrs / 1,000

Which competing models share Tech Drive FA-BF-03-L(WH) airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Air King AK80 80 / 68.8 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Commercial Electric BPT13-14D 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Commercial Electric BPT13-14HD 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Valu+ BPT13-14DT-2 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
VENTECHLATION BPT13-14DT-1 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter

How much airflow margin does Tech Drive FA-BF-03-L(WH) give your bath?

Run a quick local room-volume check for Tech Drive FA-BF-03-L(WH) by entering square footage and ceiling height to spot under-vented steam risks early.

Does Tech Drive FA-BF-03-L(WH) suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Tech Drive FA-BF-03-L(WH) for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 62 sq ft with 8-ft ceilings (55 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Tech Drive FA-BF-03-L(WH)?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Tech Drive FA-BF-03-L(WH).

Does duct resistance cut Tech Drive FA-BF-03-L(WH) airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Tech Drive FA-BF-03-L(WH) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Tech Drive FA-BF-03-L(WH) occupy in EPA filings?

With 1.5 sones at 0.1 in. w.g., Tech Drive FA-BF-03-L(WH) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Tech Drive FA-BF-03-L(WH) add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Tech Drive FA-BF-03-L(WH) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Tech Drive FA-BF-03-L(WH) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive FA-BF-03-L(WH)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Tech Drive FA-BF-03-L(WH)?

Tech Drive FA-BF-03-L(WH) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Tech Drive FA-BF-03-L(WH)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive FA-BF-03-L(WH)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Does Tech Drive FA-BF-03-L(WH) pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Tech Drive FA-BF-03-L(WH) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Tech Drive FA-BF-03-L(WH) in a bathroom remodel?

Avoid specifying Tech Drive FA-BF-03-L(WH) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources